Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 10:41:09 on December 8, 2000
Entry number 53129
keyword=Start_Run_1720_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1720 at Fri Dec 8 10:40:58 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=50000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018781
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.382
Right Arm Q2 momentum : 1.00003
Right Arm Q2 gauss meter : 0.22556
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.087
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371089
Right Arm Q3 power supply current : 398.087
Right Arm Q3 momentum : 1.00045
Right Arm Q3 gauss meter : 0.17784
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.21444
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.47
Left Arm Q2 momentum : 3.3592
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.14
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.31
Left Arm Q3 momentum : 3.35908
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 55.2949
Current on Unser monitor : 51.6873
Current on Upstream bcm : 56.4913
Current on Downstream bcm : 55.6543
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 100.851
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 17.27
haSC200_6_Sensor_3_R : 2.99
haSC200_6_Sensor_4_R : 39.86
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.76
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 67
haITC502_5_Sensor_1_R : 61.11
haITC502_5_Sensor_2_R : 59.59
haITC502_5_Sensor_3_R : 156.3
haITC502_6_Sensor_1_R : 94.77
haITC502_6_Sensor_2_R : 98.29
haITC502_6_Sensor_3_R : 26.86
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1401
HacR_VPM_LVDT:VALr : -1640
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.84082
HacR_alignROLL : -0.359887
HacR_alignPITCH : 0.00859734
HacR_alignHPT : -1.15721
HacL_HPM_LVDT:VALr : -8176
HacL_VPM_LVDT:VALr : 1351
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 24.0723
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0830634
HacL_alignPITCH : -0.12992
HacL_alignHPT : 5.36262
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5089
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7674
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 288
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88