Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 11:00:05 on December 8,2000
Entry number 53130
keyword=R-arm scint HV turned on
Just prior to run 1720 we turned on the right arm scintillator HV
for the purpose of studying triggers 1,2, and 7 parasitically.
The prescale factors were adjusted so that we keep a modest
rate and don't affect the main experiment. At 56 microamps the
rates are:
T1: 360 kHz
T2: 10 kHz
T7: 345 kHz
With the aim to keep 2 Hz of each, plus the constraint that
T5-8 can be prescaled by only 16 bits (65K) while T1-4 can
be prescaled by 24 bits, we choose ps1=180000, ps2=5000, ps7=65535.
During run 1720 we also turn on the VDC HV. The temperature
in that hut is 74.3F and it is not expected to raise the temperature
(the discriminator cards would, but they are already on).