    User name adev

    Log entry time 14:09:57 on December 8, 2000

    Entry number 53140

    keyword=End_of_Run_1724
    ****************************
     Run Number: 1724
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=23.767. Beam off to gain access to the Hall for A/C work on the Left arm.
    
    
    Time of run = 30.662093 min
    Av. current (on 3x) = 45.666321 uA
    Av. current (on 1x) = 45.64871 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   83.9811  |   84.0135  |   83.4240
    up-down    (mC)|    1.3559  |    1.4899  |    1.4801
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6591648.8 /mC  |    1.672 Hz  | 553787490  | 180000   |   6594191.9 /mC
        2      |    189548.2 /mC  |    1.731 Hz  |  15924607  |  5000   |    189621.3 /mC
        3      |      6191.4 /mC  |  282.739 Hz  |    520163  |     1   |      6193.8 /mC
        4      |    735317.1 /mC  |   16.790 Hz  |  61776563  |  2000   |    735600.8 /mC
        5      |       242.3 /mC  |    0.000 Hz  |     20354  | 65535   |       242.4 /mC
        output                       291.405 Hz
    Av. deadtime from accepted triggers = 0.0381
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  301231.56  Hz     |    300881.76 Hz   |  301016.35 Hz
        2      |  8766.0143  Hz     |    8741.8366 Hz   |  8655.9686 Hz
        3      |  283.17456  Hz     |    282.33007 Hz   |  282.73945 Hz
        4      |  33603.147  Hz     |    33565.351 Hz   |  33579.227 Hz
        5      |  11.239337  Hz     |    10.968342 Hz   |  11.063606 Hz
        output |  0.0  Hz   |    0.0 Hz |   291.405 Hz
    Accepted triggers  = 536105.00000
     Time of run = 30.662093 min
     Time of run h- = 15.157259 min
     Time of run h+ = 15.159554 min
     1-(sum of time hel + and -)/( run time) = 1.1261e-02
    Rate of Left Arm Pulser for electronic DT  = 0.0
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 0.0
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = -1
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 55637.383
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.237545  Hz         |    0.0 Hz        |  11.237545 Hz
          -        |  0.0  Hz        |    11.237545 Hz       |  11.238089 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0418788         |   0.0418261         | 0.0846591     
       upstream 3x |   0.0419271         |   0.0418758         | 0.0847584     
       upstream 10x|   0.0416304         |   0.0415851         | 0.0841641     
      downstream   |   0.0412081         |   0.0411560         | 0.0833032    
     downstream 3x |   0.0412008         |   0.0411557         | 0.0832685    
     downstream 10x|   0.0408984         |   0.0408538         | 0.0826840    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -6.29592770e-04 
       upstream 3x |   -6.12150650e-04 
       upstream 10x|   -5.44369740e-04 
      downstream   |   -6.32557150e-04 
     downstream 3x |   -5.47619190e-04 
     downstream 10x|   -5.45551070e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1724 at Fri Dec  8 14:09:43 EST 2000
    Right Arm D1 momentum                    : 1
    Right Arm arm angle                      : 12.5089
    Left Arm D1 momentum                      : 3.35929
    Left Arm arm angle                        : 23.7674
    Tiefenbach Hall A energy                : 4582.74
    Right Arm arm mispointing (HPT)          : -1.16218
    Left Arm arm mispointing (HPT)            : 5.36687
    Right Arm Q1 power supply current        : 751.87
    Right Arm Q1 momentum                    : 0.999914
    Right Arm Q1 gauss meter                 : -0.018776
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.452
    Right Arm Q2 momentum                    : 1.00014
    Right Arm Q2 gauss meter                 : 0.22548
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 343.086
    Right Arm D1 momentum                    : 1
    Right Arm D1 NMR                         : 0.371088
    Right Arm Q3 power supply current        : 397.888
    Right Arm Q3 momentum                    : 0.999949
    Right Arm Q3 gauss meter                 : 0.17782
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.49
    Left Arm Q1 momentum                      : 3.35954
    Left Arm Q1 gauss meter                   : 0.21443
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.7
    Left Arm Q2 momentum                      : 3.35972
    Left Arm Q2 gauss meter                   : -0.7615
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1193.13
    Left Arm D1 momentum                      : 3.35929
    Left Arm D1 NMR                           : 1.24416
    Left Arm Q3 power supply current          : 1337.27
    Left Arm Q3 momentum                      : 3.35898
    Left Arm Q3 gauss meter                   : 0.6671
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0334135
    Current on Unser monitor                : -2.85784
    Current on Upstream bcm                 : 0.0307824
    Current on Downstream bcm               : 0.0360447
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 45.4987
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 0.0377197
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.74
    Tiefenbach Hall C energy                : 2324.05
    Delta(E)/E width (MV_AI_DXWID)          : 2.13171
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.868506
     HacR_HPM_LVDT:VALr                     : -1397
     HacR_VPM_LVDT:VALr                     : -1642
     HacR_HPE1313A:0_Ch58                   : -0.567871
     HacR_HPE1313A:0_Ch55                   : 22.9004
     HacR_HPE1313A:0_Ch54                   : -0.840332
     HacR_alignROLL                         : -0.359016
     HacR_alignPITCH                        : 0.00962678
     HacR_alignHPT                          : -1.16218
     HacL_HPM_LVDT:VALr                     : -8182
     HacL_VPM_LVDT:VALr                     : 1346
     HacL_HPE1313A:0_Ch58                   : -0.129883
     HacL_HPE1313A:0_Ch55                   : 24.0234
     HacL_HPE1313A:0_Ch54                   : -0.282227
     HacL_alignROLL                         : 0.0834349
     HacL_alignPITCH                        : -0.129845
     HacL_alignHPT                          : 5.36579
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 63
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 23.32
    haH2_P_Exhaust_R                         : 23.45
    haH2_P_Fill_Bottle_R                     : 23.82
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.714
    haSC200_6_Sensor_1_R                     : 242.1
    haSC200_6_Sensor_2_R                     : 17.23
    haSC200_6_Sensor_3_R                     : 2.99
    haSC200_6_Sensor_4_R                     : 39.86
    haHe_Omega_DPG_Sensor_R                  : -0.029
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 90.43
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 76.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 67
    haITC502_5_Sensor_1_R                    : 61.29
    haITC502_5_Sensor_2_R                    : 59.72
    haITC502_5_Sensor_3_R                    : 154.8
    haITC502_6_Sensor_1_R                    : 94.8
    haITC502_6_Sensor_2_R                    : 98.33
    haITC502_6_Sensor_3_R                    : 26.84
    Right Arm Arm Collimator                 : 0.363916
    Left Arm Arm Collimator                   : 0.868506
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 100
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : OFF