User name adev
Log entry time 23:07:34 on December 8, 2000
Entry number 53156
keyword=Start_Run_1730_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1730 at Fri Dec 8 23:07:03 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018775
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.354
Right Arm Q2 momentum : 0.999969
Right Arm Q2 gauss meter : 0.22557
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.086
Right Arm D1 momentum : 0.999999
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.953
Right Arm Q3 momentum : 0.999588
Right Arm Q3 gauss meter : 0.17781
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.67
Left Arm Q2 momentum : 3.35967
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.13
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.51
Left Arm Q3 momentum : 3.35958
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 53.75
Current on Unser monitor : 51.1446
Current on Upstream bcm : 53.7092
Current on Downstream bcm : 53.7909
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 113.776
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.25
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 39.96
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.19
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.9
haITC502_5_Sensor_1_R : 61.13
haITC502_5_Sensor_2_R : 59.6
haITC502_5_Sensor_3_R : 153.3
haITC502_6_Sensor_1_R : 94.43
haITC502_6_Sensor_2_R : 97.88
haITC502_6_Sensor_3_R : 26.77
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1394
HacR_VPM_LVDT:VALr : -1634
HacR_HPE1313A:0_Ch58 : -0.566406
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.84082
HacR_alignROLL : -0.360059
HacR_alignPITCH : 0.00879472
HacR_alignHPT : -1.16606
HacL_HPM_LVDT:VALr : -8200
HacL_VPM_LVDT:VALr : 1345
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0829225
HacL_alignPITCH : -0.129771
HacL_alignHPT : 5.38838
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5089
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7672
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 287
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88