Log entry time 13:56:32 on December 9, 2000
Entry number 53201
keyword=Start_Run_1746_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1746 at Sat Dec 9 13:56:20 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018776
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.382
Right Arm Q2 momentum : 1.00003
Right Arm Q2 gauss meter : 0.22555
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.094
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371089
Right Arm Q3 power supply current : 398.124
Right Arm Q3 momentum : 1.00054
Right Arm Q3 gauss meter : 0.17785
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.72
Left Arm Q2 momentum : 3.35977
Left Arm Q2 gauss meter : -0.7616
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.69
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.32
Left Arm Q3 momentum : 3.35909
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 55.0793
Current on Unser monitor : 51.6402
Current on Upstream bcm : 55.5714
Current on Downstream bcm : 54.5871
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 56.0562
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00122
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.3
haSC200_6_Sensor_2_R : 17.22
haSC200_6_Sensor_3_R : 3.02
haSC200_6_Sensor_4_R : 40.01
haHe_Omega_DPG_Sensor_R : -0.03
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.17
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 61.24
haITC502_5_Sensor_2_R : 59.66
haITC502_5_Sensor_3_R : 152.7
haITC502_6_Sensor_1_R : 94.59
haITC502_6_Sensor_2_R : 98.04
haITC502_6_Sensor_3_R : 26.74
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1377
HacR_VPM_LVDT:VALr : -1659
HacR_HPE1313A:0_Ch58 : -0.566406
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.837891
HacR_alignROLL : -0.355943
HacR_alignPITCH : 0.00859734
HacR_alignHPT : -1.18632
HacL_HPM_LVDT:VALr : -8208
HacL_VPM_LVDT:VALr : 1310
HacL_HPE1313A:0_Ch58 : -0.130371
HacL_HPE1313A:0_Ch55 : 24.0234
HacL_HPE1313A:0_Ch54 : -0.283691
HacL_alignROLL : 0.0829225
HacL_alignPITCH : -0.128897
HacL_alignHPT : 5.40067
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 314
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88