User name adev
Log entry time 14:51:49 on December 9, 2000
Entry number 53203
keyword=Start_Run_1747_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1747 at Sat Dec 9 14:51:40 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018781
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.52
Right Arm Q2 momentum : 1.00036
Right Arm Q2 gauss meter : 0.22552
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.093
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.863
Right Arm Q3 momentum : 0.999886
Right Arm Q3 gauss meter : 0.17783
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.4
Left Arm Q2 momentum : 3.35904
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.69
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.39
Left Arm Q3 momentum : 3.35927
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 54.8369
Current on Unser monitor : 54.576
Current on Upstream bcm : 55.1324
Current on Downstream bcm : 54.5414
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 103.959
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.31
haSC200_6_Sensor_2_R : 17.2
haSC200_6_Sensor_3_R : 3.06
haSC200_6_Sensor_4_R : 40.04
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.26
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 61.05
haITC502_5_Sensor_2_R : 59.55
haITC502_5_Sensor_3_R : 152.8
haITC502_6_Sensor_1_R : 94.61
haITC502_6_Sensor_2_R : 98.08
haITC502_6_Sensor_3_R : 26.74
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1382
HacR_VPM_LVDT:VALr : -1656
HacR_HPE1313A:0_Ch58 : -0.566406
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.836914
HacR_alignROLL : -0.356
HacR_alignPITCH : 0.00821421
HacR_alignHPT : -1.18069
HacL_HPM_LVDT:VALr : -8211
HacL_VPM_LVDT:VALr : 1311
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.283691
HacL_alignROLL : 0.0815971
HacL_alignPITCH : -0.129334
HacL_alignHPT : 5.40466
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.509
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 315
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88