User name adev
Log entry time 05:39:59 on December 10, 2000
Entry number 53242
keyword=Start_Run_1765_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1765 at Sun Dec 10 05:39:45 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018778
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.399
Right Arm Q2 momentum : 1.00007
Right Arm Q2 gauss meter : 0.22545
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.093
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 398.047
Right Arm Q3 momentum : 1.00035
Right Arm Q3 gauss meter : 0.17787
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.73
Left Arm Q2 momentum : 3.35981
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.69
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.29
Left Arm Q3 momentum : 3.35903
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 56.6708
Current on Unser monitor : 54.2941
Current on Upstream bcm : 55.4272
Current on Downstream bcm : 57.9144
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 101.166
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.3
haSC200_6_Sensor_2_R : 17.17
haSC200_6_Sensor_3_R : 3.02
haSC200_6_Sensor_4_R : 39.98
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.01
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 61.37
haITC502_5_Sensor_2_R : 59.72
haITC502_5_Sensor_3_R : 151.4
haITC502_6_Sensor_1_R : 94.85
haITC502_6_Sensor_2_R : 98.33
haITC502_6_Sensor_3_R : 26.71
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1370
HacR_VPM_LVDT:VALr : -1660
HacR_HPE1313A:0_Ch58 : -0.567383
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.836426
HacR_alignROLL : -0.354956
HacR_alignPITCH : 0.00859734
HacR_alignHPT : -1.1936
HacL_HPM_LVDT:VALr : -8216
HacL_VPM_LVDT:VALr : 1299
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0824103
HacL_alignPITCH : -0.12926
HacL_alignHPT : 5.40763
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle :
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 321
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88