User name adev
Log entry time 06:35:21 on December 10, 2000
Entry number 53245
keyword=Start_Run_1766_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1766 at Sun Dec 10 06:35:09 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.835
Right Arm Q1 momentum : 0.999867
Right Arm Q1 gauss meter : -0.018779
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.526
Right Arm Q2 momentum : 1.00037
Right Arm Q2 gauss meter : 0.22552
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.094
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.746
Right Arm Q3 momentum : 0.99959
Right Arm Q3 gauss meter : 0.17779
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.21421
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.58
Left Arm Q2 momentum : 3.3597
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.43
Left Arm Q3 momentum : 3.35937
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 56.9637
Current on Unser monitor : 53.9202
Current on Upstream bcm : 56.5093
Current on Downstream bcm : 57.418
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 99.4372
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.1
haSC200_6_Sensor_3_R : 3.06
haSC200_6_Sensor_4_R : 39.99
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.72
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.5
haITC502_5_Sensor_1_R : 61.45
haITC502_5_Sensor_2_R : 59.79
haITC502_5_Sensor_3_R : 151.4
haITC502_6_Sensor_1_R : 94.88
haITC502_6_Sensor_2_R : 98.36
haITC502_6_Sensor_3_R : 26.71
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1367
HacR_VPM_LVDT:VALr : -1659
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.835938
HacR_alignROLL : -0.354956
HacR_alignPITCH : 0.0081484
HacR_alignHPT : -1.19807
HacL_HPM_LVDT:VALr : -8217
HacL_VPM_LVDT:VALr : 1298
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0824103
HacL_alignPITCH : -0.128386
HacL_alignHPT : 5.40986
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field :
Laser attenuation Hall A : 322
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88