Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 13:08:22 on December 10, 2000
Entry number 53261
keyword=Start_Run_1773_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1773 at Sun Dec 10 13:08:10 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018769
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.392
Right Arm Q2 momentum : 1.00006
Right Arm Q2 gauss meter : 0.22553
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.095
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 398.123
Right Arm Q3 momentum : 1.00054
Right Arm Q3 gauss meter : 0.17785
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.67
Left Arm Q2 momentum : 3.35967
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.56
Left Arm Q3 momentum : 3.35971
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 57.661
Current on Unser monitor : 54.316
Current on Upstream bcm : 57.4436
Current on Downstream bcm : 57.8783
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 58.9534
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.13
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 39.99
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.73
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 61.2
haITC502_5_Sensor_2_R : 59.59
haITC502_5_Sensor_3_R : 154.3
haITC502_6_Sensor_1_R : 94.87
haITC502_6_Sensor_2_R : 98.33
haITC502_6_Sensor_3_R : 26.68
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1366
HacR_VPM_LVDT:VALr : -1648
HacR_HPE1313A:0_Ch58 : -0.567383
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.835449
HacR_alignROLL : -0.354899
HacR_alignPITCH : 0.00898051
HacR_alignHPT : -1.20035
HacL_HPM_LVDT:VALr : -8222
HacL_VPM_LVDT:VALr : 1306
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0828521
HacL_alignPITCH : -0.12926
HacL_alignHPT : 5.41412
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.767
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 245
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88