User name adev
Log entry time 19:56:30 on December 10, 2000
Entry number 53283
keyword=Start_Run_1783_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1783 at Sun Dec 10 19:56:20 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018776
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.388
Right Arm Q2 momentum : 1.00005
Right Arm Q2 gauss meter : 0.22546
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.094
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.694
Right Arm Q3 momentum : 0.99946
Right Arm Q3 gauss meter : 0.17774
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.49
Left Arm Q2 momentum : 3.35925
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.69
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.27
Left Arm Q3 momentum : 3.35898
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 44.0856
Current on Unser monitor : 43.0461
Current on Upstream bcm : 43.9299
Current on Downstream bcm : 44.2414
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 94.1649
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.4
haSC200_6_Sensor_2_R : 17.17
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 39.98
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.79
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 61.51
haITC502_5_Sensor_2_R : 59.88
haITC502_5_Sensor_3_R : 154.9
haITC502_6_Sensor_1_R : 95.01
haITC502_6_Sensor_2_R : 98.49
haITC502_6_Sensor_3_R : 26.67
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1365
HacR_VPM_LVDT:VALr : -1658
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.835938
HacR_alignROLL : -0.354899
HacR_alignPITCH : 0.00853154
HacR_alignHPT : -1.20035
HacL_HPM_LVDT:VALr : -8228
HacL_VPM_LVDT:VALr : 1294
HacL_HPE1313A:0_Ch58 : -0.130859
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0828521
HacL_alignPITCH : -0.128386
HacL_alignHPT : 5.4197
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.767
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 248
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88