Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:14:04 on December 10, 2000
Entry number 53296
keyword=Start_Run_1789_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1789 at Sun Dec 10 23:13:49 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018778
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.362
Right Arm Q2 momentum : 0.999988
Right Arm Q2 gauss meter : 0.22545
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.087
Right Arm D1 momentum : 0.999998
Right Arm D1 NMR : 0.371087
Right Arm Q3 power supply current : 397.666
Right Arm Q3 momentum : 0.99939
Right Arm Q3 gauss meter : 0.17776
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.48
Left Arm Q2 momentum : 3.35923
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.34
Left Arm Q3 momentum : 3.35915
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.2949
Current on Unser monitor : 54.9453
Current on Upstream bcm : 57.7061
Current on Downstream bcm : 58.8838
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 116.534
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.15873
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.35
haSC200_6_Sensor_2_R : 17.22
haSC200_6_Sensor_3_R : 3.02
haSC200_6_Sensor_4_R : 40.01
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.05
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.9
haITC502_5_Sensor_1_R : 61.57
haITC502_5_Sensor_2_R : 59.89
haITC502_5_Sensor_3_R : 154.9
haITC502_6_Sensor_1_R : 95.07
haITC502_6_Sensor_2_R : 98.54
haITC502_6_Sensor_3_R : 26.66
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1362
HacR_VPM_LVDT:VALr : -1659
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.836426
HacR_alignROLL : -0.355392
HacR_alignPITCH : 0.00898051
HacR_alignHPT : -1.20342
HacL_HPM_LVDT:VALr : -8224
HacL_VPM_LVDT:VALr : 1294
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.0824807
HacL_alignPITCH : -0.128024
HacL_alignHPT : 5.41765
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.767
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 284
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88