Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 07:37:26 on December 11, 2000
Entry number 53323
keyword=Start_Run_1800_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1800 at Mon Dec 11 07:37:15 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.01877
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.229
Right Arm Q2 momentum : 0.999679
Right Arm Q2 gauss meter : 0.22553
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.095
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.835
Right Arm Q3 momentum : 0.999813
Right Arm Q3 gauss meter : 0.17782
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21421
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.49
Left Arm Q2 momentum : 3.35924
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.45
Left Arm Q3 momentum : 3.35943
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 55.8877
Current on Unser monitor : 52.8066
Current on Upstream bcm : 55.5311
Current on Downstream bcm : 55.3812
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 104.29
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.38
haSC200_6_Sensor_2_R : 17.17
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 40.08
haHe_Omega_DPG_Sensor_R : -0.036
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.87
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 61.55
haITC502_5_Sensor_2_R : 59.91
haITC502_5_Sensor_3_R : 157.2
haITC502_6_Sensor_1_R : 95.11
haITC502_6_Sensor_2_R : 98.6
haITC502_6_Sensor_3_R : 26.64
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1364
HacR_VPM_LVDT:VALr : -1656
HacR_HPE1313A:0_Ch58 : -0.567871
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.837891
HacR_alignROLL : -0.355828
HacR_alignPITCH : 0.00936374
HacR_alignHPT : -1.20206
HacL_HPM_LVDT:VALr : -8220
HacL_VPM_LVDT:VALr : 1294
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 24.0234
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.082993
HacL_alignPITCH : -0.128098
HacL_alignHPT : 5.41181
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.767
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 302
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88