Main INDEX
Monthly INDEX
PREV
NEXT
User name LeRose
Log entry time 16:04:04 on December11,2000
Entry number 53354
keyword=Shift summary
08:00 run 1800 underway
RF problems around noon turn out to be short lived
Continuing problems with script to check FPP and calorimeter giving false alarms
~13:00 notice a shift in the calorimeter missing energy spectrum. Closer inspection shows gradual shift over 2-3 runs with large shifts coming at run 1806.
(See halog 53344)
Suspect that effect may be from stray field from the right dipole. This is also probably related to the FFP and calorimeter script alarm of earlier (be careful what you call a false alarm)
On-line analysis of run 1808 verifies the above suspision. Emiss spectrum is shifting back to where it was before the magnet was ramped up. Ramp up of dipole started about 11:30. Max current reached at about 13:00. Ramp down started 14:27. (see halog entries marked "magnet tests")
14:05 Harp scan scan1179.data
run........start/stop......Events....comments
1800....07:37/08:37....1.0M .......good run
1801....08:37/09:28....1.0M........good run
1802....09:28/10:26....1.0M........good run
1803....10:26/11:15....0.87M......stopped for FPP HV trip
1804....11:17/12:06....0.69M......stopped for RF problems
1805....12:08/13:09....1.0M........good run
1806....13:09/14:00....0.83M......stopped for beam off (Right Dipole at max)
1807....14:18/15:12....1.0M........good run (right Dipole field dropping)
1808....15:13 passed on to next shift...........
Total events: 7.39M