User name adev
Log entry time 11:10:50 on December 12, 2000
Entry number 53395
keyword=Start_Run_1825_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1825 at Tue Dec 12 11:10:40 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.71e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.146563
Right Arm Q2 momentum : 0.000340553
Right Arm Q2 gauss meter : 0.0005844
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97665
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.6154
Right Arm Q3 power supply current : -0.0202559
Right Arm Q3 momentum : -5.09059e-05
Right Arm Q3 gauss meter : 0.0002706
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.53
Left Arm Q2 momentum : 3.35934
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.52
Left Arm Q3 momentum : 3.35959
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0327732
Current on Unser monitor : -2.4224
Current on Upstream bcm : 0.029918
Current on Downstream bcm : 0.0356284
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.48
haSC200_6_Sensor_2_R : 17.22
haSC200_6_Sensor_3_R : 3.09
haSC200_6_Sensor_4_R : 40.18
haHe_Omega_DPG_Sensor_R : -0.03
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.07
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.5
haITC502_4_Sensor_2_R : 18.7
haITC502_4_Sensor_3_R : 67
haITC502_5_Sensor_1_R : 61.79
haITC502_5_Sensor_2_R : 60.14
haITC502_5_Sensor_3_R : 153.8
haITC502_6_Sensor_1_R : 95.37
haITC502_6_Sensor_2_R : 98.84
haITC502_6_Sensor_3_R : 26.58
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1356
HacR_VPM_LVDT:VALr : -1647
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.839355
HacR_alignROLL : -0.357422
HacR_alignPITCH : 0.0112911
HacR_alignHPT : -1.20898
HacL_HPM_LVDT:VALr : -8209
HacL_VPM_LVDT:VALr : 1303
HacL_HPE1313A:0_Ch58 : -0.132324
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0824807
HacL_alignPITCH : -0.127151
HacL_alignHPT : 5.402
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88