User name adev
Log entry time 21:46:17 on December 12, 2000
Entry number 53422
keyword=Start_Run_1836_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1836 at Tue Dec 12 21:46:01 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.2e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.0978506
Right Arm Q2 momentum : 0.000227365
Right Arm Q2 gauss meter : 0.0006109
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97743
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.28696
Right Arm Q3 power supply current : 0.12351
Right Arm Q3 momentum : 0.000310399
Right Arm Q3 gauss meter : 0.0002789
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21421
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.71
Left Arm Q2 momentum : 3.35976
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.44
Left Arm Q3 momentum : 3.3594
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.4419
Current on Unser monitor : 54.5811
Current on Upstream bcm : 58.1392
Current on Downstream bcm : 58.6055
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 110.156
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.43
haSC200_6_Sensor_2_R : 17.12
haSC200_6_Sensor_3_R : 3.06
haSC200_6_Sensor_4_R : 40.14
haHe_Omega_DPG_Sensor_R : -0.034
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.97
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 61.86
haITC502_5_Sensor_2_R : 60.17
haITC502_5_Sensor_3_R : 152.9
haITC502_6_Sensor_1_R : 95.47
haITC502_6_Sensor_2_R : 98.94
haITC502_6_Sensor_3_R : 26.54
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1342
HacR_VPM_LVDT:VALr : -1640
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.838379
HacR_alignROLL : -0.357857
HacR_alignPITCH : 0.0116743
HacR_alignHPT : -1.22441
HacL_HPM_LVDT:VALr : -8219
HacL_VPM_LVDT:VALr : 1311
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.0832235
HacL_alignPITCH : -0.128312
HacL_alignHPT : 5.41059
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5093
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 328
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88