User name adev
Log entry time 04:18:33 on December 13, 2000
Entry number 53447
keyword=Start_Run_1847_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1847 at Wed Dec 13 04:18:20 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.76e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.326556
Right Arm Q2 momentum : 0.000758785
Right Arm Q2 gauss meter : 0.0005909
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97663
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.61619
Right Arm Q3 power supply current : 0.237955
Right Arm Q3 momentum : 0.000598015
Right Arm Q3 gauss meter : 0.0002734
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.42
Left Arm Q1 momentum : 3.35945
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.6
Left Arm Q2 momentum : 3.35949
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.45
Left Arm Q3 momentum : 3.35943
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 59.8345
Current on Unser monitor : 55.4098
Current on Upstream bcm : 59.1709
Current on Downstream bcm : 60.4982
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 105.549
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.38
haSC200_6_Sensor_2_R : 17.1
haSC200_6_Sensor_3_R : 3.01
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.53
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 61.64
haITC502_5_Sensor_2_R : 59.92
haITC502_5_Sensor_3_R : 153.3
haITC502_6_Sensor_1_R : 95.58
haITC502_6_Sensor_2_R : 99.09
haITC502_6_Sensor_3_R : 26.52
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1342
HacR_VPM_LVDT:VALr : -1628
HacR_HPE1313A:0_Ch58 : -0.568848
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.839844
HacR_alignROLL : -0.358901
HacR_alignPITCH : 0.0103931
HacR_alignHPT : -1.22605
HacL_HPM_LVDT:VALr : -8219
HacL_VPM_LVDT:VALr : 1322
HacL_HPE1313A:0_Ch58 : -0.131836
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0819684
HacL_alignPITCH : -0.127875
HacL_alignHPT : 5.41011
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5093
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 385
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88