Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 06:10:13 on December 13, 2000
Entry number 53454
keyword=Start_Run_1850_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1850 at Wed Dec 13 06:10:01 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.33e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.118152
Right Arm Q2 momentum : 0.000274538
Right Arm Q2 gauss meter : 0.0006168
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97693
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.77709
Right Arm Q3 power supply current : -0.0346589
Right Arm Q3 momentum : -8.71026e-05
Right Arm Q3 gauss meter : 0.0002789
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21422
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.43
Left Arm Q2 momentum : 3.3591
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.62
Left Arm Q3 momentum : 3.35985
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 61.4613
Current on Unser monitor : 58.1182
Current on Upstream bcm : 61.0271
Current on Downstream bcm : 61.8954
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 104.964
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.4
haSC200_6_Sensor_2_R : 17.13
haSC200_6_Sensor_3_R : 3.02
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.73
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.5
haITC502_5_Sensor_1_R : 61.91
haITC502_5_Sensor_2_R : 60.19
haITC502_5_Sensor_3_R : 153.5
haITC502_6_Sensor_1_R : 95.56
haITC502_6_Sensor_2_R : 99.02
haITC502_6_Sensor_3_R : 26.52
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1336
HacR_VPM_LVDT:VALr : -1630
HacR_HPE1313A:0_Ch58 : -0.569336
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.838867
HacR_alignROLL : -0.357915
HacR_alignPITCH : 0.0108421
HacR_alignHPT : -1.23109
HacL_HPM_LVDT:VALr : -8218
HacL_VPM_LVDT:VALr : 1321
HacL_HPE1313A:0_Ch58 : -0.130859
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0815971
HacL_alignPITCH : -0.128897
HacL_alignHPT : 5.41137
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5094
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 400
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88