• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 02:14:28 on December 14, 2000

    Entry number 53488

    keyword=Start_Run_1860_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
    Beginning-of-run EPICS data for Run Number 1860 at Thu Dec 14 02:14:19 EST 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
    
    
    
    
    
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0
    Right Arm Q1 gauss meter                 : 1.42e-05
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 0.288333
    Right Arm Q2 momentum                    : 0.00066997
    Right Arm Q2 gauss meter                 : 0.0005778
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1.97697
    Right Arm D1 momentum                    : 0
    Right Arm D1 NMR                         : 0.931951
    Right Arm Q3 power supply current        : 0.0861958
    Right Arm Q3 momentum                    : 0.000216622
    Right Arm Q3 gauss meter                 : 0.0002287
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.49
    Left Arm Q1 momentum                      : 3.35954
    Left Arm Q1 gauss meter                   : 0.21419
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.55
    Left Arm Q2 momentum                      : 3.35939
    Left Arm Q2 gauss meter                   : -0.7614
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.68
    Left Arm D1 momentum                      : 3.3593
    Left Arm D1 NMR                           : 1.24416
    Left Arm Q3 power supply current          : 1337.3
    Left Arm Q3 momentum                      : 3.35906
    Left Arm Q3 gauss meter                   : 0.6672
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0323791
    Current on Unser monitor                : -2.74277
    Current on Upstream bcm                 : 0.0294421
    Current on Downstream bcm               : 0.035316
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 11.9323
    Beam energy                             : 4592.25
    MBSY1c magnet current (amp)             : 191.553
     Radiator 5V Linear Supply              : 5.00122
     Radiator Encoder                       : 0.153846
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62.5
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 242.28
    haSC200_6_Sensor_2_R                     : 17.15
    haSC200_6_Sensor_3_R                     : 2.97
    haSC200_6_Sensor_4_R                     : 39.96
    haHe_Omega_DPG_Sensor_R                  : -0.029
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 90.46
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 76.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 66.9
    haITC502_5_Sensor_1_R                    : 61.59
    haITC502_5_Sensor_2_R                    : 60
    haITC502_5_Sensor_3_R                    : 154.9
    haITC502_6_Sensor_1_R                    : 95.56
    haITC502_6_Sensor_2_R                    : 99.03
    haITC502_6_Sensor_3_R                    : 26.51
    Right Arm Arm Collimator                 : 0.363916
    Left Arm Arm Collimator                   : 0.868359
     HacR_HPM_LVDT:VALr                     : -1352
     HacR_VPM_LVDT:VALr                     : -1609
     HacR_HPE1313A:0_Ch58                   : -0.568848
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.841309
     HacR_alignROLL                         : -0.360002
     HacR_alignPITCH                        : 0.0114225
     HacR_alignHPT                          : -1.21199
     HacL_HPM_LVDT:VALr                     : -8128
     HacL_VPM_LVDT:VALr                     : 1391
     HacL_HPE1313A:0_Ch58                   : -0.130371
     HacL_HPE1313A:0_Ch55                   : 23.8281
     HacL_HPE1313A:0_Ch54                   : -0.282715
     HacL_alignROLL                         : 0.0823398
     HacL_alignPITCH                        : -0.129185
     HacL_alignHPT                          : 5.31157
    Right Arm Angle Floor Angle               : 12.5
    Right Arm Angle Vernier                   : -34
    Right Arm Scattering Angle                : 12.5092
    Left Arm Angle Floor Angle                 : 24
    Left Arm Angle Vernier                     : -3
    Left Arm Scattering Angle                  : 23.7677
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 120
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : OFF
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88