User name adev
Log entry time 05:42:03 on December 14, 2000
Entry number 53498
keyword=Start_Run_1865_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1865 at Thu Dec 14 05:41:52 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.4e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.119636
Right Arm Q2 momentum : 0.000277987
Right Arm Q2 gauss meter : 0.0006118
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.9764
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.993191
Right Arm Q3 power supply current : 0.167257
Right Arm Q3 momentum : 0.00042034
Right Arm Q3 gauss meter : 0.0002294
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.62
Left Arm Q2 momentum : 3.35954
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.29
Left Arm Q3 momentum : 3.35949
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 60.2422
Current on Unser monitor : 55.8847
Current on Upstream bcm : 60.0343
Current on Downstream bcm : 60.4502
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 105.84
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.3
haSC200_6_Sensor_2_R : 17.15
haSC200_6_Sensor_3_R : 2.99
haSC200_6_Sensor_4_R : 39.99
haHe_Omega_DPG_Sensor_R : -0.033
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.28
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.9
haITC502_5_Sensor_1_R : 62.08
haITC502_5_Sensor_2_R : 60.39
haITC502_5_Sensor_3_R : 159.6
haITC502_6_Sensor_1_R : 95.9
haITC502_6_Sensor_2_R : 99.38
haITC502_6_Sensor_3_R : 26.5
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1359
HacR_VPM_LVDT:VALr : -1620
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.842285
HacR_alignROLL : -0.361424
HacR_alignPITCH : 0.0118057
HacR_alignHPT : -1.20334
HacL_HPM_LVDT:VALr : -8120
HacL_VPM_LVDT:VALr : 1382
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0823398
HacL_alignPITCH : -0.129622
HacL_alignHPT : 5.30151
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 293
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88