User name adev
Log entry time 17:40:43 on December 14, 2000
Entry number 53528
keyword=Start_Run_1877_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1877 at Thu Dec 14 17:40:31 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.19e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.247127
Right Arm Q2 momentum : 0.000574223
Right Arm Q2 gauss meter : 0.0006085
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.9769
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.00182
Right Arm Q3 power supply current : 0.232764
Right Arm Q3 momentum : 0.000584969
Right Arm Q3 gauss meter : 0.0002304
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21417
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.32
Left Arm Q2 momentum : 3.35884
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.48
Left Arm Q3 momentum : 3.3595
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 61.6116
Current on Unser monitor : 56.8824
Current on Upstream bcm : 61.2905
Current on Downstream bcm : 61.9326
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 62.0003
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.31
haSC200_6_Sensor_2_R : 17.18
haSC200_6_Sensor_3_R : 2.96
haSC200_6_Sensor_4_R : 40.09
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.17
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 67
haITC502_5_Sensor_1_R : 62.12
haITC502_5_Sensor_2_R : 60.41
haITC502_5_Sensor_3_R : 159.1
haITC502_6_Sensor_1_R : 96.12
haITC502_6_Sensor_2_R : 99.62
haITC502_6_Sensor_3_R : 26.46
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1372
HacR_VPM_LVDT:VALr : -1625
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.84375
HacR_alignROLL : -0.363018
HacR_alignPITCH : 0.0114882
HacR_alignHPT : -1.18788
HacL_HPM_LVDT:VALr : -8116
HacL_VPM_LVDT:VALr : 1388
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0827112
HacL_alignPITCH : -0.129547
HacL_alignHPT : 5.29574
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 337
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88