User name adev
Log entry time 20:33:04 on December 14, 2000
Entry number 53540
keyword=Start_Run_1882_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1882 at Thu Dec 14 20:32:53 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.95e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.297231
Right Arm Q2 momentum : 0.000690645
Right Arm Q2 gauss meter : 0.0005968
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97708
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.2812
Right Arm Q3 power supply current : 0.174355
Right Arm Q3 momentum : 0.000438179
Right Arm Q3 gauss meter : 0.0002206
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21415
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.45
Left Arm Q2 momentum : 3.35915
Left Arm Q2 gauss meter : -0.7613
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.44
Left Arm Q3 momentum : 3.35939
Left Arm Q3 gauss meter : 0.667
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 59.1053
Current on Unser monitor : 54.2124
Current on Upstream bcm : 59.1716
Current on Downstream bcm : 59.0391
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 106.782
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.26
haSC200_6_Sensor_2_R : 17.2
haSC200_6_Sensor_3_R : 2.99
haSC200_6_Sensor_4_R : 40.11
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.35
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 67
haITC502_5_Sensor_1_R : 62.25
haITC502_5_Sensor_2_R : 60.54
haITC502_5_Sensor_3_R : 157
haITC502_6_Sensor_1_R : 96.18
haITC502_6_Sensor_2_R : 99.68
haITC502_6_Sensor_3_R : 26.46
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1365
HacR_VPM_LVDT:VALr : -1627
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.84375
HacR_alignROLL : -0.363018
HacR_alignPITCH : 0.0119371
HacR_alignHPT : -1.1946
HacL_HPM_LVDT:VALr : -8117
HacL_VPM_LVDT:VALr : 1388
HacL_HPE1313A:0_Ch58 : -0.128906
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0822693
HacL_alignPITCH : -0.129984
HacL_alignHPT : 5.29707
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 345
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88