Log entry time 01:49:12 on December 15, 2000
Entry number 53557
keyword=Start_Run_1889_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1889 at Fri Dec 15 01:48:57 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.39e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.31654
Right Arm Q2 momentum : 0.000735512
Right Arm Q2 gauss meter : 0.0005759
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97769
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.993538
Right Arm Q3 power supply current : 0.183594
Right Arm Q3 momentum : 0.000461396
Right Arm Q3 gauss meter : 0.0002209
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.49
Left Arm Q2 momentum : 3.35926
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.62
Left Arm Q3 momentum : 3.35985
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 52.5872
Current on Unser monitor : 48.4382
Current on Upstream bcm : 52.3911
Current on Downstream bcm : 52.7833
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 52.2166
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.31
haSC200_6_Sensor_2_R : 17.05
haSC200_6_Sensor_3_R : 3.01
haSC200_6_Sensor_4_R : 40.14
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.45
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19.3
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 62.21
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 157.1
haITC502_6_Sensor_1_R : 96.18
haITC502_6_Sensor_2_R : 99.67
haITC502_6_Sensor_3_R : 26.43
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1364
HacR_VPM_LVDT:VALr : -1624
HacR_HPE1313A:0_Ch58 : -0.571289
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.845703
HacR_alignROLL : -0.365047
HacR_alignPITCH : 0.0129007
HacR_alignHPT : -1.19568
HacL_HPM_LVDT:VALr : -8116
HacL_VPM_LVDT:VALr : 1396
HacL_HPE1313A:0_Ch58 : -0.128418
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0826408
HacL_alignPITCH : -0.130346
HacL_alignHPT : 5.29578
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 329
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88