User name adev
Log entry time 09:06:36 on December 15, 2000
Entry number 53578
keyword=Start_Run_1898_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1898 at Fri Dec 15 09:06:25 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.01e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.134797
Right Arm Q2 momentum : 0.000313213
Right Arm Q2 gauss meter : 0.0006128
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97608
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.795178
Right Arm Q3 power supply current : -0.0227574
Right Arm Q3 momentum : -5.71924e-05
Right Arm Q3 gauss meter : 0.0002199
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.44
Left Arm Q2 momentum : 3.35914
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.48
Left Arm Q3 momentum : 3.35951
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 59.4254
Current on Unser monitor : 54.4039
Current on Upstream bcm : 59.0395
Current on Downstream bcm : 59.8113
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 105.914
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.13
haSC200_6_Sensor_3_R : 3.02
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 0
haITC502_1_Sensor_2_R : 89.64
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 62.2
haITC502_5_Sensor_2_R : 60.42
haITC502_5_Sensor_3_R : 156.9
haITC502_6_Sensor_1_R : 96.27
haITC502_6_Sensor_2_R : 99.78
haITC502_6_Sensor_3_R : 26.42
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1369
HacR_VPM_LVDT:VALr : -1622
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.845703
HacR_alignROLL : -0.365597
HacR_alignPITCH : 0.0120686
HacR_alignHPT : -1.18977
HacL_HPM_LVDT:VALr : -8113
HacL_VPM_LVDT:VALr : 1402
HacL_HPE1313A:0_Ch58 : -0.12793
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.0830121
HacL_alignPITCH : -0.130709
HacL_alignHPT : 5.29225
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7679
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 352
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88