    User name adev

    Log entry time 17:38:03 on December 17, 2000

    Entry number 53750

    keyword=End_of_Run_1969
    ****************************
     Run Number: 1969
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
    
    
    Time of run = 14.895638 min
    Av. current (on 3x) = 43.114747 uA
    Av. current (on 1x) = 43.017291 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   38.4462  |   38.5333  |   38.2330
    up-down    (mC)|    0.5496  |    0.4557  |    0.7288
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6425707.9 /mC  |    1.539 Hz  | 247603730  | 180000   |   6440265.4 /mC
        2      |    101728.7 /mC  |    0.877 Hz  |   3919941  |  5000   |    101959.1 /mC
        3      |      6429.4 /mC  |  277.201 Hz  |    247745  |     1   |      6443.9 /mC
        4      |    750299.5 /mC  |   16.174 Hz  |  28911517  |  2000   |    751999.3 /mC
        5      |       600.1 /mC  |    0.000 Hz  |     23124  | 65535   |       601.5 /mC
        output                       257.005 Hz
    Av. deadtime from accepted triggers = 0.1311
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  276913.14  Hz     |    277163.49 Hz   |  277042.77 Hz
        2      |  4385.7832  Hz     |    4393.9062 Hz   |  4386.0055 Hz
        3      |  275.54346  Hz     |    278.7717 Hz   |  277.20084 Hz
        4      |  32332.32  Hz     |    32366.934 Hz   |  32348.975 Hz
        5      |  25.845213  Hz     |    25.944937 Hz   |  25.873346 Hz
        output |  0.0  Hz   |    0.0 Hz |   257.005 Hz
    Accepted triggers  = 229695.00000
     Time of run = 14.895638 min
     Time of run h- = 7.3636718 min
     Time of run h+ = 7.3643555 min
     1-(sum of time hel + and -)/( run time) = 1.1252e-02
    Rate of Left Arm Pulser for electronic DT  = 10.166287
    Rate of Right Arm Pulser for electronic DT  = 5.013772
    Rate of Left Arm Pulser&trig for electronic DT  = 10.113699
    Rate of Right Arm Pulser&trig for electronic DT  = 5.013772
    Left Arm Electronic DT  = 0.0051727933
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 54205.25
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.252735  Hz         |    0.0 Hz        |  11.252735 Hz
          -        |  0.0  Hz        |    11.251616 Hz       |  11.252735 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0191341         |   0.0191497         | 0.0387210     
       upstream 3x |   0.0191539         |   0.0191692         | 0.0387612     
       upstream 10x|   0.0190740         |   0.0190877         | 0.0385974     
      downstream   |   0.0188627         |   0.0188777         | 0.0381714    
     downstream 3x |   0.0189291         |   0.0189435         | 0.0383055    
     downstream 10x|   0.0187141         |   0.0187269         | 0.0378686    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   4.07483060e-04 
       upstream 3x |   3.99237010e-04 
       upstream 10x|   3.58998680e-04 
      downstream   |   3.97452070e-04 
     downstream 3x |   3.80222110e-04 
     downstream 10x|   3.41871210e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1969 at Sun Dec 17 17:37:46 EST 2000
    Right Arm D1 momentum                    : 1
    Right Arm arm angle                      : 12.5091
    Left Arm D1 momentum                      : 3.3593
    Left Arm arm angle                        : 23.7678
    Tiefenbach Hall A energy                : 4582.73
    Right Arm arm mispointing (HPT)          : -1.18677
    Left Arm arm mispointing (HPT)            : 5.29663
    Right Arm Q1 power supply current        : 751.87
    Right Arm Q1 momentum                    : 0.999914
    Right Arm Q1 gauss meter                 : -0.018772
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.507
    Right Arm Q2 momentum                    : 1.00032
    Right Arm Q2 gauss meter                 : 0.22553
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 342.996
    Right Arm D1 momentum                    : 1
    Right Arm D1 NMR                         : 0.371088
    Right Arm Q3 power supply current        : 397.972
    Right Arm Q3 momentum                    : 0.999675
    Right Arm Q3 gauss meter                 : 0.17785
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.59
    Left Arm Q1 momentum                      : 3.35968
    Left Arm Q1 gauss meter                   : 0.21418
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.33
    Left Arm Q2 momentum                      : 3.35887
    Left Arm Q2 gauss meter                   : -0.7613
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.66
    Left Arm D1 momentum                      : 3.3593
    Left Arm D1 NMR                           : 1.24416
    Left Arm Q3 power supply current          : 1337.57
    Left Arm Q3 momentum                      : 3.35974
    Left Arm Q3 gauss meter                   : 0.6672
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 56.5375
    Current on Unser monitor                : 52.0165
    Current on Upstream bcm                 : 57.0811
    Current on Downstream bcm               : 55.994
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 102.37
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.74
    Tiefenbach Hall C energy                : 2323.92
    Delta(E)/E width (MV_AI_DXWID)          : 2.12277
    IPM1C12.XPOS                            : 0.00360259
    IPM1H04A.XPOS                           : 0.403351
    IPM1H04A.YPOS                           : 0.990853
    IPM1H04B.XPOS                           : -0.0293705
    IPM1H04B.YPOS                           : 0.210692
    Right Arm Arm Collimator                 : 0.364014
    Left Arm Arm Collimator                   : 0.868506
     HacR_HPM_LVDT:VALr                     : -1373
     HacR_VPM_LVDT:VALr                     : -1673
     HacR_HPE1313A:0_Ch58                   : -0.570312
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.843262
     HacR_alignROLL                         : -0.362525
     HacR_alignPITCH                        : 0.0114882
     HacR_alignHPT                          : -1.18704
     HacL_HPM_LVDT:VALr                     : -8115
     HacL_VPM_LVDT:VALr                     : 1352
     HacL_HPE1313A:0_Ch58                   : -0.128418
     HacL_HPE1313A:0_Ch55                   : 23.7793
     HacL_HPE1313A:0_Ch54                   : -0.282715
     HacL_alignROLL                         : 0.0817571
     HacL_alignPITCH                        : -0.129473
     HacL_alignHPT                          : 5.29509
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 61.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.15
    haH2_P_Exhaust_R                         : 22.3
    haH2_P_Fill_Bottle_R                     : 22.55
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.783
    haSC200_6_Sensor_1_R                     : 242.55
    haSC200_6_Sensor_2_R                     : 17.09
    haSC200_6_Sensor_3_R                     : 3.07
    haSC200_6_Sensor_4_R                     : 40.14
    haHe_Omega_DPG_Sensor_R                  : -0.029
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 89.48
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 18.99
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.17
    haITC502_4_Sensor_1_R                    : 76.3
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 66.8
    haITC502_5_Sensor_1_R                    : 62.72
    haITC502_5_Sensor_2_R                    : 
    haITC502_5_Sensor_3_R                    : 157
    haITC502_6_Sensor_1_R                    : 96.99
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 26.28
    Right Arm Arm Collimator                 : 0.364014
    Left Arm Arm Collimator                   : 0.868506
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 395
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : ON