Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 17:41:31 on December 17, 2000
Entry number 53751
keyword=Start_Run_1970_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1970 at Sun Dec 17 17:41:20 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018772
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.539
Right Arm Q2 momentum : 1.0004
Right Arm Q2 gauss meter : 0.22553
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.993
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.906
Right Arm Q3 momentum : 0.999993
Right Arm Q3 gauss meter : 0.17787
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21418
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.52
Left Arm Q2 momentum : 3.3593
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.66
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.3
Left Arm Q3 momentum : 3.35905
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 57.6968
Current on Unser monitor : 53.271
Current on Upstream bcm : 57.4836
Current on Downstream bcm : 57.91
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 104.699
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.53
haSC200_6_Sensor_2_R : 17.09
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 40.18
haHe_Omega_DPG_Sensor_R : -0.036
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.35
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 62.76
haITC502_5_Sensor_2_R : 60.91
haITC502_5_Sensor_3_R : 157
haITC502_6_Sensor_1_R : 96.99
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.29
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1372
HacR_VPM_LVDT:VALr : -1673
HacR_HPE1313A:0_Ch58 : -0.569336
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.842285
HacR_alignROLL : -0.361538
HacR_alignPITCH : 0.0110393
HacR_alignHPT : -1.18873
HacL_HPM_LVDT:VALr : -8116
HacL_VPM_LVDT:VALr : 1351
HacL_HPE1313A:0_Ch58 : -0.128418
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0817571
HacL_alignPITCH : -0.130346
HacL_alignHPT : 5.2962
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 399
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88