User name adev
Log entry time 23:03:36 on December 17, 2000
Entry number 53763
keyword=Start_Run_1976_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1976 at Sun Dec 17 23:03:26 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018767
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.557
Right Arm Q2 momentum : 0.999864
Right Arm Q2 gauss meter : 0.22558
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.002
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371089
Right Arm Q3 power supply current : 397.907
Right Arm Q3 momentum : 0.999997
Right Arm Q3 gauss meter : 0.17781
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.49
Left Arm Q2 momentum : 3.35924
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.47
Left Arm Q3 momentum : 3.35947
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.3108
Current on Unser monitor : 49.6417
Current on Upstream bcm : 57.4118
Current on Downstream bcm : 59.2098
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 59.6216
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 17.09
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 40.14
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.86
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.5
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.9
haITC502_5_Sensor_1_R : 62.79
haITC502_5_Sensor_2_R : 60.96
haITC502_5_Sensor_3_R : 159.7
haITC502_6_Sensor_1_R : 96.98
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.27
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1368
HacR_VPM_LVDT:VALr : -1668
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.843262
HacR_alignROLL : -0.362525
HacR_alignPITCH : 0.0123861
HacR_alignHPT : -1.19264
HacL_HPM_LVDT:VALr : -8124
HacL_VPM_LVDT:VALr : 1359
HacL_HPE1313A:0_Ch58 : -0.128906
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.283691
HacL_alignROLL : 0.0813154
HacL_alignPITCH : -0.12991
HacL_alignHPT : 5.30535
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 455
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88