Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 03:09:21 on December 18, 2000
Entry number 53775
keyword=Start_Run_1981_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1981 at Mon Dec 18 03:09:05 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018772
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.349
Right Arm Q2 momentum : 0.999826
Right Arm Q2 gauss meter : 0.22554
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.994
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.803
Right Arm Q3 momentum : 0.999734
Right Arm Q3 gauss meter : 0.17779
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.32
Left Arm Q2 momentum : 3.35886
Left Arm Q2 gauss meter : -0.7613
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.48
Left Arm Q3 momentum : 3.3595
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.4373
Current on Unser monitor : 52.018
Current on Upstream bcm : 58.4727
Current on Downstream bcm : 58.402
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 104.85
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.43
haSC200_6_Sensor_2_R : 17.07
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 40.11
haHe_Omega_DPG_Sensor_R : -0.03
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.06
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.5
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 62.73
haITC502_5_Sensor_2_R : 60.96
haITC502_5_Sensor_3_R : 160.6
haITC502_6_Sensor_1_R : 97.04
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.26
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1367
HacR_VPM_LVDT:VALr : -1660
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.84375
HacR_alignROLL : -0.363075
HacR_alignPITCH : 0.0124518
HacR_alignHPT : -1.19345
HacL_HPM_LVDT:VALr : -8120
HacL_VPM_LVDT:VALr : 1365
HacL_HPE1313A:0_Ch58 : -0.128906
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.283691
HacL_alignROLL : 0.0821285
HacL_alignPITCH : -0.129399
HacL_alignHPT : 5.3005
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 457
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88