User name adev
Log entry time 05:09:09 on December 18, 2000
Entry number 53780
keyword=Start_Run_1983_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1983 at Mon Dec 18 05:08:56 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.045
Right Arm Q1 momentum : 1.00015
Right Arm Q1 gauss meter : -0.018773
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.211
Right Arm Q2 momentum : 0.999637
Right Arm Q2 gauss meter : 0.22556
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.995
Right Arm D1 momentum : 0.999999
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.657
Right Arm Q3 momentum : 0.999369
Right Arm Q3 gauss meter : 0.17778
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.52
Left Arm Q2 momentum : 3.35932
Left Arm Q2 gauss meter : -0.7613
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.5
Left Arm Q3 momentum : 3.35955
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0298911
Current on Unser monitor : -3.69719
Current on Upstream bcm : 0.0268065
Current on Downstream bcm : 0.0329756
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.41
haSC200_6_Sensor_2_R : 17.02
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 40.09
haHe_Omega_DPG_Sensor_R : -0.034
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.5
haITC502_4_Sensor_2_R : 18.7
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 62.68
haITC502_5_Sensor_2_R : 60.94
haITC502_5_Sensor_3_R : 160.8
haITC502_6_Sensor_1_R : 97.05
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.25
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1369
HacR_VPM_LVDT:VALr : -1655
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.84375
HacR_alignROLL : -0.363075
HacR_alignPITCH : 0.0120029
HacR_alignHPT : -1.19121
HacL_HPM_LVDT:VALr : -8126
HacL_VPM_LVDT:VALr : 1370
HacL_HPE1313A:0_Ch58 : -0.128418
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0830825
HacL_alignPITCH : -0.129473
HacL_alignHPT : 5.30339
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88