User name adev
Log entry time 17:41:26 on December 18, 2000
Entry number 53805
keyword=Start_Run_1991_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1991 at Mon Dec 18 17:41:11 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.01878
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.488
Right Arm Q2 momentum : 1.00028
Right Arm Q2 gauss meter : 0.22553
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.994
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.922
Right Arm Q3 momentum : 1.00003
Right Arm Q3 gauss meter : 0.17779
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21418
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.48
Left Arm Q2 momentum : 3.35923
Left Arm Q2 gauss meter : -0.7613
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.44
Left Arm Q3 momentum : 3.3594
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 59.3197
Current on Unser monitor : 54.3612
Current on Upstream bcm : 58.196
Current on Downstream bcm : 57.4056
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 58.6508
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.05
haSC200_6_Sensor_3_R : 3.01
haSC200_6_Sensor_4_R : 40.04
haHe_Omega_DPG_Sensor_R : -0.035
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.8
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 62.43
haITC502_5_Sensor_2_R : 60.65
haITC502_5_Sensor_3_R : 159.9
haITC502_6_Sensor_1_R : 96.88
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.22
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1364
HacR_VPM_LVDT:VALr : -1645
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.84375
HacR_alignROLL : -0.363568
HacR_alignPITCH : 0.0120029
HacR_alignHPT : -1.19541
HacL_HPM_LVDT:VALr : -8116
HacL_VPM_LVDT:VALr : 1394
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0826408
HacL_alignPITCH : -0.12991
HacL_alignHPT : 5.29801
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 416
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88