    User name adev

    Log entry time 22:40:33 on December 18, 2000

    Entry number 53821

    keyword=End_of_Run_1997
    ****************************
     Run Number: 1997
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
    
    
    Time of run = 51.517367 min
    Av. current (on 3x) = 49.654744 uA
    Av. current (on 1x) = 49.545461 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  153.1471  |  153.4849  |  151.6291
    up-down    (mC)|    2.0785  |    1.7462  |    2.9605
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6385712.5 /mC  |    1.762 Hz  | 980110450  | 180000   |   6399797.6 /mC
        2      |    107219.4 /mC  |    1.065 Hz  |  16456554  |  5000   |    107455.9 /mC
        3      |      6350.4 /mC  |  315.325 Hz  |    974684  |     1   |      6364.4 /mC
        4      |    742205.3 /mC  |   18.427 Hz  | 113917310  |  2000   |    743842.4 /mC
        5      |       591.2 /mC  |    0.000 Hz  |     90744  | 65535   |       592.5 /mC
        output                       323.522 Hz
    Av. deadtime from accepted triggers = 0.0388
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  316977.68  Hz     |    317312.29 Hz   |  317080.92 Hz
        2      |  5322.9153  Hz     |    5338.9378 Hz   |  5323.9503 Hz
        3      |  315.80553  Hz     |    314.96632 Hz   |  315.32538 Hz
        4      |  36849.328  Hz     |    36877.09 Hz   |  36854.015 Hz
        5      |  29.310692  Hz     |    29.549667 Hz   |  29.357091 Hz
        output |  0.0  Hz   |    0.0 Hz |   323.522 Hz
    Accepted triggers  = 1000021.00000
     Time of run = 51.517367 min
     Time of run h- = 25.469548 min
     Time of run h+ = 25.468522 min
     1-(sum of time hel + and -)/( run time) = 1.1245e-02
    Rate of Left Arm Pulser for electronic DT  = 10.171004
    Rate of Right Arm Pulser for electronic DT  = 4.9840798
    Rate of Left Arm Pulser&trig for electronic DT  = 10.114712
    Rate of Right Arm Pulser&trig for electronic DT  = 4.9840798
    Left Arm Electronic DT  = 0.0055345272
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 61567.535
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.233752  Hz         |    0.0 Hz        |  11.234076 Hz
          -        |  0.0  Hz        |    11.234076 Hz       |  11.234076 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0761977         |   0.0762818         | 0.1541863     
       upstream 3x |   0.0762824         |   0.0763650         | 0.1543580     
       upstream 10x|   0.0756686         |   0.0757413         | 0.1531093     
      downstream   |   0.0751705         |   0.0752537         | 0.1521078    
     downstream 3x |   0.0754195         |   0.0754999         | 0.1526118    
     downstream 10x|   0.0742058         |   0.0742756         | 0.1501488    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   5.51549550e-04 
       upstream 3x |   5.41116320e-04 
       upstream 10x|   4.80153540e-04 
      downstream   |   5.53102490e-04 
     downstream 3x |   5.32734690e-04 
     downstream 10x|   4.70092550e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1997 at Mon Dec 18 22:40:20 EST 2000
    Right Arm D1 momentum                    : 0.999999
    Right Arm arm angle                      : 12.5091
    Left Arm D1 momentum                      : 3.35931
    Left Arm arm angle                        : 23.7678
    Tiefenbach Hall A energy                : 4582.74
    Right Arm arm mispointing (HPT)          : -1.19761
    Left Arm arm mispointing (HPT)            : 5.29641
    Right Arm Q1 power supply current        : 752.01
    Right Arm Q1 momentum                    : 1.0001
    Right Arm Q1 gauss meter                 : -0.018768
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.369
    Right Arm Q2 momentum                    : 1
    Right Arm Q2 gauss meter                 : 0.22552
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 342.995
    Right Arm D1 momentum                    : 0.999999
    Right Arm D1 NMR                         : 0.371088
    Right Arm Q3 power supply current        : 398.02
    Right Arm Q3 momentum                    : 1.00028
    Right Arm Q3 gauss meter                 : 0.17785
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.59
    Left Arm Q1 momentum                      : 3.35968
    Left Arm Q1 gauss meter                   : 0.21417
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.68
    Left Arm Q2 momentum                      : 3.35968
    Left Arm Q2 gauss meter                   : -0.7614
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.67
    Left Arm D1 momentum                      : 3.35931
    Left Arm D1 NMR                           : 1.24417
    Left Arm Q3 power supply current          : 1337.25
    Left Arm Q3 momentum                      : 3.35892
    Left Arm Q3 gauss meter                   : 0.6671
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 60.136
    Current on Unser monitor                : 54.9612
    Current on Upstream bcm                 : 59.7998
    Current on Downstream bcm               : 59.1904
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 106.785
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.74
    Tiefenbach Hall C energy                : 2323.87
    Delta(E)/E width (MV_AI_DXWID)          : 2.12604
    IPM1C12.XPOS                            : -0.0006136
    IPM1H04A.XPOS                           : 0.282656
    IPM1H04A.YPOS                           : 0.77032
    IPM1H04B.XPOS                           : -0.0508436
    IPM1H04B.YPOS                           : -0.0672709
    Right Arm Arm Collimator                 : 0.364014
    Left Arm Arm Collimator                   : 0.868457
     HacR_HPM_LVDT:VALr                     : -1362
     HacR_VPM_LVDT:VALr                     : -1657
     HacR_HPE1313A:0_Ch58                   : -0.571777
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.844238
     HacR_alignROLL                         : -0.363625
     HacR_alignPITCH                        : 0.0129664
     HacR_alignHPT                          : -1.19761
     HacL_HPM_LVDT:VALr                     : -8114
     HacL_VPM_LVDT:VALr                     : 1381
     HacL_HPE1313A:0_Ch58                   : -0.129395
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.282715
     HacL_alignROLL                         : 0.0813154
     HacL_alignPITCH                        : -0.12991
     HacL_alignHPT                          : 5.29418
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 21.58
    haH2_P_Exhaust_R                         : 21.67
    haH2_P_Fill_Bottle_R                     : 22.04
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.646
    haSC200_6_Sensor_1_R                     : 242.28
    haSC200_6_Sensor_2_R                     : 17.04
    haSC200_6_Sensor_3_R                     : 3.02
    haSC200_6_Sensor_4_R                     : 40.04
    haHe_Omega_DPG_Sensor_R                  : -0.03
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 89.64
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 18.99
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.18
    haITC502_4_Sensor_1_R                    : 76.4
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 66.7
    haITC502_5_Sensor_1_R                    : 62.92
    haITC502_5_Sensor_2_R                    : 61.06
    haITC502_5_Sensor_3_R                    : 155.6
    haITC502_6_Sensor_1_R                    : 97.2
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 26.2
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.868457
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 424
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : ON