Log entry time 00:22:41 on December 19, 2000
Entry number 53832
keyword=Start_Run_2001_Tar=carbon,Type=Optics,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 2001 at Tue Dec 19 00:22:29 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.045
Right Arm Q1 momentum : 1.00015
Right Arm Q1 gauss meter : -0.018777
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.39
Right Arm Q2 momentum : 1.00005
Right Arm Q2 gauss meter : 0.22549
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.987
Right Arm D1 momentum : 0.999998
Right Arm D1 NMR : 0.371087
Right Arm Q3 power supply current : 397.939
Right Arm Q3 momentum : 1.00008
Right Arm Q3 gauss meter : 0.17783
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21416
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.35
Left Arm Q2 momentum : 3.35892
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.57
Left Arm Q3 momentum : 3.35973
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 59.4597
Current on Unser monitor : 55.8134
Current on Upstream bcm : 59.5446
Current on Downstream bcm : 59.6941
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 107.594
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.156288
haBDSPOS : 732012
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.26
haSC200_6_Sensor_2_R : 17.02
haSC200_6_Sensor_3_R : 2.97
haSC200_6_Sensor_4_R : 40.03
haHe_Omega_DPG_Sensor_R : -0.03
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.47
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 62.75
haITC502_5_Sensor_2_R : 61
haITC502_5_Sensor_3_R : 159.2
haITC502_6_Sensor_1_R : 97.25
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.47
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1382
HacR_VPM_LVDT:VALr : -1658
HacR_HPE1313A:0_Ch58 : -0.571289
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.844727
HacR_alignROLL : -0.363683
HacR_alignPITCH : 0.013032
HacR_alignHPT : -1.17519
HacL_HPM_LVDT:VALr : -8106
HacL_VPM_LVDT:VALr : 1388
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0821285
HacL_alignPITCH : -0.129835
HacL_alignHPT : 5.28485
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.509
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7679
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 433
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88