    User name R. Michaels

    Log entry time 02:18:46 on December19,2000

    Entry number 53853

    keyword=X = -1mm, HARP scan

    We move the beam to X = -1 mm
    EPICS says, X,Y = -1.0, 0
    Spot says -1.5, +0.5 (calib. seems off)
    Harp scan (plot below), run 1174 (73 was junk). CODA run 2010

    Survey offsets: X(5)=-0.07 Y(5)= 0.08 X(6)=-0.45 Y(6)=-0.23 mm
    dz4A = 7345.00 dz4B = 2214.00

    ***************************************************************
    Uncorrected Corrected Sigma
    position position Width
    Scanner #5 4ax: 406.0um 336.0um 119.0um
    Scanner #5 4ay: 1186.00um 1266.00um 23.0um
    Scanner #6 4bx: 1545.00um 1095.00um 96.0um
    Scanner #6 4by: 757.00um 527.00um 41.9um

    ***************************************************************
    Uncorrected Corrected
    position position
    Target x pos : 2036.47 um 1422.50 um (+ for beam left)
    Target y pos : 571.89 um 208.13 um (+ for too high)
    Beam h angle: -0.22 mrad -0.15 mrad (+ for clockwise)
    Beam v slope: -0.08 mrad -0.14 mrad (+ for ascending slope)
    ***************************************************************




    FIGURE 1