User name adev
Log entry time 04:05:08 on December 19, 2000
Entry number 53864
keyword=Start_Run_2014_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 2014 at Tue Dec 19 04:04:57 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018767
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.22
Right Arm Q2 momentum : 0.999657
Right Arm Q2 gauss meter : 0.22552
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.996
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.939
Right Arm Q3 momentum : 1.00008
Right Arm Q3 gauss meter : 0.17788
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.73
Left Arm Q2 momentum : 3.35981
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.66
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.23
Left Arm Q3 momentum : 3.35888
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 14.1757
Current on Unser monitor : 10.9602
Current on Upstream bcm : 13.7034
Current on Downstream bcm : 14.6481
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 35.162
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.15873
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.71
haSC200_6_Sensor_2_R : 17.2
haSC200_6_Sensor_3_R : 3.22
haSC200_6_Sensor_4_R : 40.14
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 91.1
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.6
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 67
haITC502_5_Sensor_1_R : 63.13
haITC502_5_Sensor_2_R : 61.37
haITC502_5_Sensor_3_R : 152.7
haITC502_6_Sensor_1_R : 98.03
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.22
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1375
HacR_VPM_LVDT:VALr : -1666
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.843262
HacR_alignROLL : -0.361917
HacR_alignPITCH : 0.0118057
HacR_alignHPT : -1.18515
HacL_HPM_LVDT:VALr : -8124
HacL_VPM_LVDT:VALr : 1370
HacL_HPE1313A:0_Ch58 : -0.12793
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0822693
HacL_alignPITCH : -0.130857
HacL_alignHPT : 5.3049
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 212
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88