User name adev
Log entry time 04:25:45 on December 19, 2000
Entry number 53865
keyword=End_of_Run_2014
****************************
Run Number: 2014
End of Run Comment:
Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Time of run = 21.16198 min
Av. current (on 3x) = 42.220372 uA
Av. current (on 1x) = 42.126335 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 53.4886 | 53.6080 | 52.9865
up-down (mC)| 0.7108 | 0.5808 | 1.0172
Trigger | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 6391666.9 /mC | 1.499 Hz | 342644480 | 180000 | 6405934.7 /mC
2 | 141005.2 /mC | 1.191 Hz | 7559009 | 5000 | 141320.0 /mC
3 | 6412.5 /mC | 270.739 Hz | 343762 | 1 | 6426.8 /mC
4 | 739564.5 /mC | 15.612 Hz | 39646573 | 2000 | 741215.4 /mC
5 | 620.1 /mC | 0.000 Hz | 33240 | 65535 | 621.4 /mC
output 277.958 Hz
Av. deadtime from accepted triggers = 0.0383
Av. deadtime from gated scalers = 1.0000
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 269755.37 Hz | 270033.65 Hz | 269858.55 Hz
2 | 5946.3492 Hz | 5974.8063 Hz | 5953.2938 Hz
3 | 270.45597 Hz | 271.07569 Hz | 270.73869 Hz
4 | 31213.648 Hz | 31248.932 Hz | 31224.688 Hz
5 | 25.901483 Hz | 26.568833 Hz | 26.179025 Hz
output | 0.0 Hz | 0.0 Hz | 277.958 Hz
Accepted triggers = 352929.00000
Time of run = 21.16198 min
Time of run h- = 10.46276 min
Time of run h+ = 10.460791 min
1-(sum of time hel + and -)/( run time) = 1.1267e-02
Rate of Left Arm Pulser for electronic DT = 10.169181
Rate of Right Arm Pulser for electronic DT = 4.9412516
Rate of Left Arm Pulser&trig for electronic DT = 10.116413
Rate of Right Arm Pulser&trig for electronic DT = 4.9412516
Left Arm Electronic DT = 0.0051889715
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 52331.058
Rate of Right Arm Strobe = 0.0
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 11.234771 Hz | 0.0 Hz | 11.235559 Hz
- | 0.0 Hz | 11.235559 Hz | 11.235559 Hz
Signal | Gate on + and run | Gate on - and run | Gate on run |
| Charge (C) | Charge (C) | Charge (C)
upstream | 0.0266073 | 0.0266380 | 0.0538440
upstream 3x | 0.0266345 | 0.0266646 | 0.0538984
upstream 10x| 0.0264360 | 0.0264631 | 0.0534951
downstream | 0.0262561 | 0.0262863 | 0.0531332
downstream 3x | 0.0263477 | 0.0263770 | 0.0533176
downstream 10x| 0.0259336 | 0.0259596 | 0.0524779
Signal | Asymmetry
|
upstream | 5.76576710e-04
upstream 3x | 5.64737490e-04
upstream 10x| 5.12296050e-04
downstream | 5.74773900e-04
downstream 3x | 5.55716770e-04
downstream 10x| 5.01029040e-04
****************************
End-of-run EPICS data for Run Number 2014 at Tue Dec 19 04:25:33 EST 2000
Right Arm D1 momentum : 1
Right Arm arm angle : 12.5091
Left Arm D1 momentum : 3.35931
Left Arm arm angle : 23.7678
Tiefenbach Hall A energy : 4582.74
Right Arm arm mispointing (HPT) : -1.19407
Left Arm arm mispointing (HPT) : 5.30025
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018773
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.236
Right Arm Q2 momentum : 1.00008
Right Arm Q2 gauss meter : 0.22546
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.997
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.905
Right Arm Q3 momentum : 0.999992
Right Arm Q3 gauss meter : 0.17788
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.31
Left Arm Q2 momentum : 3.35883
Left Arm Q2 gauss meter : -0.7613
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.66
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.47
Left Arm Q3 momentum : 3.35948
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.0288
Current on Unser monitor : 52.9465
Current on Upstream bcm : 57.0554
Current on Downstream bcm : 58.7906
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 106.244
MBSY1c Hall A Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
MBSY1c Bdl : 1.146e+06
MBSY3c Hall C Beam energy : 2329.44
Tiefenbach Hall A energy : 4582.73
Tiefenbach Hall C energy : 2323.84
Delta(E)/E width (MV_AI_DXWID) : 2.1204
IPM1C12.XPOS : -0.0035117
IPM1H04A.XPOS : 0.623365
IPM1H04A.YPOS : 0.802355
IPM1H04B.XPOS : -0.00743937
IPM1H04B.YPOS : 0.00712597
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1367
HacR_VPM_LVDT:VALr : -1672
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.842773
HacR_alignROLL : -0.361974
HacR_alignPITCH : 0.0118715
HacR_alignHPT : -1.19519
HacL_HPM_LVDT:VALr : -8120
HacL_VPM_LVDT:VALr : 1365
HacL_HPE1313A:0_Ch58 : -0.128418
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.083153
HacL_alignPITCH : -0.130421
HacL_alignHPT : 5.3
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 21.53
haH2_P_Exhaust_R : 21.63
haH2_P_Fill_Bottle_R : 22.01
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.563
haSC200_6_Sensor_1_R : 242.63
haSC200_6_Sensor_2_R : 17.15
haSC200_6_Sensor_3_R : 3.16
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 91.22
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.19
haITC502_4_Sensor_1_R : 76.7
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 68.4
haITC502_5_Sensor_1_R : 63.34
haITC502_5_Sensor_2_R : 61.51
haITC502_5_Sensor_3_R : 153
haITC502_6_Sensor_1_R : 98.01
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.21
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868506
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 420
Laser power Hall A : 73
Half-wave plate (off=out) : ON