User name adev
Log entry time 04:47:17 on December 19, 2000
Entry number 53868
keyword=Start_Run_2016_Tar=LH2-15cm,Type=Elastic,Lmom=2.0,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 2016 at Tue Dec 19 04:47:03 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=80,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018774
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.513
Right Arm Q2 momentum : 1.00034
Right Arm Q2 gauss meter : 0.22554
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.988
Right Arm D1 momentum : 0.999999
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.909
Right Arm Q3 momentum : 1
Right Arm Q3 gauss meter : 0.17789
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1504.69
Left Arm Q1 momentum : 2.00003
Left Arm Q1 gauss meter : 0.12794
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 861.459
Left Arm Q2 momentum : 2.0006
Left Arm Q2 gauss meter : -0.454
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 665.072
Left Arm D1 momentum : 1.96902
Left Arm D1 NMR : 0.728611
Left Arm Q3 power supply current : 796.096
Left Arm Q3 momentum : 1.99965
Left Arm Q3 gauss meter : 0.3974
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 56.6403
Current on Unser monitor : 54.0537
Current on Upstream bcm : 58.2491
Current on Downstream bcm : 55.0316
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 104.384
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.61
haSC200_6_Sensor_2_R : 17.1
haSC200_6_Sensor_3_R : 3.12
haSC200_6_Sensor_4_R : 40.09
haHe_Omega_DPG_Sensor_R : -0.033
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 91.16
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.8
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 68.9
haITC502_5_Sensor_1_R : 63.41
haITC502_5_Sensor_2_R : 61.6
haITC502_5_Sensor_3_R : 153.4
haITC502_6_Sensor_1_R : 98
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.21
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1364
HacR_VPM_LVDT:VALr : -1675
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.842285
HacR_alignROLL : -0.361481
HacR_alignPITCH : 0.0118715
HacR_alignHPT : -1.19771
HacL_HPM_LVDT:VALr : -8134
HacL_VPM_LVDT:VALr : 1348
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.279785
HacL_alignROLL : 0.0844784
HacL_alignPITCH : -0.130421
HacL_alignHPT : 5.31501
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7677
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 428
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88