User name adev
Log entry time 05:21:33 on December 19, 2000
Entry number 53873
keyword=Start_Run_2018_Tar=LH2-15cm,Type=Elastic,Lmom=1.0,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 2018 at Tue Dec 19 05:21:21 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=80,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018779
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.335
Right Arm Q2 momentum : 0.999925
Right Arm Q2 gauss meter : 0.22545
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.987
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.959
Right Arm Q3 momentum : 1.00013
Right Arm Q3 gauss meter : 0.17784
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 752.115
Left Arm Q1 momentum : 0.999712
Left Arm Q1 gauss meter : 0.06437
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 430.564
Left Arm Q2 momentum : 0.999917
Left Arm Q2 gauss meter : -0.2272
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 331.7
Left Arm D1 momentum : 0.995556
Left Arm D1 NMR : 0.369295
Left Arm Q3 power supply current : 398.047
Left Arm Q3 momentum : 0.999819
Left Arm Q3 gauss meter : 0.19959
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0307487
Current on Unser monitor : -4.1817
Current on Upstream bcm : 0.0275548
Current on Downstream bcm : 0.0339426
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.48
haSC200_6_Sensor_2_R : 17.1
haSC200_6_Sensor_3_R : 3.12
haSC200_6_Sensor_4_R : 40.06
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.85
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.8
haITC502_4_Sensor_2_R : 18.8
haITC502_4_Sensor_3_R : 68.3
haITC502_5_Sensor_1_R : 63.23
haITC502_5_Sensor_2_R : 61.45
haITC502_5_Sensor_3_R : 153.6
haITC502_6_Sensor_1_R : 97.95
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 26.21
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -1368
HacR_VPM_LVDT:VALr : -1671
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.842773
HacR_alignROLL : -0.36296
HacR_alignPITCH : 0.0127693
HacR_alignHPT : -1.19239
HacL_HPM_LVDT:VALr : -8143
HacL_VPM_LVDT:VALr : 1340
HacL_HPE1313A:0_Ch58 : -0.130859
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.278809
HacL_alignROLL : 0.0861751
HacL_alignPITCH : -0.1286
HacL_alignHPT : 5.32446
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7676
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88