Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 17:22:49 on January 2,2001
Entry number 53914
keyword=DAQ L-arm config, detmap mods
Three things to report:
1. At present, the Left Spectrometer single-arm DAQ is ``working''
(of course with several things still unplugged like A1,A2 and who knows
what other small bugs). As usual, use RunControl on adaqs2 but select
the configuration "lspect" (means Left Spectr.)
2. The detector map was updated. These mods so far: a) Shower map from
Armen. b) TDC 1875 moved to slot 3, scint plane S2 now occupies 9th thru 14th
channels because discriminator inputs moved to accomodate new trigger definition.
The ADC map didn't change because I moved cables at patch panel (it must be
checked with data). Added 2 ADC 1881Ms to slots 22,23. Added 1 TDC 1877
to slot 4. All fastbus modules in ROC2 (L-arm) now get their gates from the
fastbus backplane and are ganged together in multiblock readout, with EXCEPTION
of the lone TDC 1875. ROC3 (the FPP crate) does not exist anymore.
3. Trigger mods. Both arms now define the main scintillator trigger as the simple
overlap of S1 and S2 planes. First, the Left and Right PMTs of each paddle are
AND'd (as before). Next, the OR of the 6 S1 paddles are formed. Similarly S2.
Finally, an overlap of S1,S2.
-----
The R-arm trigger & DAQ not working yet.