User name adev
Log entry time 10:43:26 on January 7, 2001
Entry number 53987
keyword=End_of_Run_1049
End-of-run EPICS data for Run Number 1049 at Sun Jan 7 10:43:15 EST 2001
Right Arm D1 momentum : 0
Right Arm arm angle : 0
Left Arm D1 momentum : 0
Left Arm arm angle : 0
Tiefenbach Hall A energy : 1173.86
Right Arm arm mispointing (HPT) : 0
Left Arm arm mispointing (HPT) : 0
Right Arm Q1 power supply current : 1e+06
Right Arm Q1 momentum : 1329.9
Right Arm Q1 gauss meter : 1.78e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.000721749
Right Arm Q2 momentum : -1.67705e-06
Right Arm Q2 gauss meter : 0.0005874
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : -0.0177458
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.395929
Right Arm Q3 power supply current : -0.000270831
Right Arm Q3 momentum : -6.80637e-07
Right Arm Q3 gauss meter : 0.0002105
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1e+06
Left Arm Q1 momentum : 1329.2
Left Arm Q1 gauss meter : 0.0004247
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : -0.000505151
Left Arm Q2 momentum : -1.17313e-06
Left Arm Q2 gauss meter : -0.0007977
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1.78278e-05
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.287561
Left Arm Q3 power supply current : 0.00013886
Left Arm Q3 momentum : 3.4879e-07
Left Arm Q3 gauss meter : 0.0015885
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0
Current on Unser monitor : 12.4416
Current on Upstream bcm : 0
Current on Downstream bcm : 0
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 0
Current on IBC0L02 (source) : 1.47562
MBSY1c Hall A Beam energy : 1174.81
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 293175
MBSY3c Hall C Beam energy : 3403.81
Tiefenbach Hall A energy : 1173.86
Tiefenbach Hall C energy : 3394.83
Delta(E)/E width (MV_AI_DXWID) : 1.45296
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -921
HacR_VPM_LVDT:VALr : -1813
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.873047
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
HacL_HPM_LVDT:VALr : -7185
HacL_VPM_LVDT:VALr : -205
HacL_HPE1313A:0_Ch58 : -0.165527
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.288086
HacL_alignROLL : 0
HacL_alignPITCH : 0
HacL_alignHPT : 0
haBDSPOS : 0
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 16.39
haH2_P_Exhaust_R : 16.88
haH2_P_Fill_Bottle_R : 16.97
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 29.89
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 27.61
haD2_DP_Fill_Exhaust_R : 0.0751
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 14.88
haSC200_6_Sensor_3_R : 3.14
haSC200_6_Sensor_4_R : 39.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 0
haITC502_1_Sensor_2_R : 0
haITC502_1_Sensor_3_R : 0
haITC502_2_Sensor_1_R : 0
haITC502_2_Sensor_2_R : 0
haITC502_2_Sensor_3_R : 0
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 0
haITC502_6_Sensor_2_R : 0
haITC502_6_Sensor_3_R : 0
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.868311
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 100
Laser power Hall A : 57
Half-wave plate (off=out) : ON