Log entry time 10:04:51 on January 9, 2001
Entry number 54092
keyword=Start_Run_1096_Tar=absence,Type=Pulser,Lmom=1.0,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1096 at Tue Jan 9 10:04:28 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 526.19
Right Arm Q1 momentum : 0.699781
Right Arm Q1 gauss meter : -0.013142
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.402
Right Arm Q2 momentum : 0.700336
Right Arm Q2 gauss meter : 0.15787
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 207.25
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.194157
Right Arm Q3 power supply current : 278.344
Right Arm Q3 momentum : 0.699913
Right Arm Q3 gauss meter : 0.12439
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.68
Left Arm Q1 momentum : 0.699971
Left Arm Q1 gauss meter : 0.04519
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 301.457
Left Arm Q2 momentum : 0.700086
Left Arm Q2 gauss meter : -0.15873
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 233.651
Left Arm D1 momentum : 0.700016
Left Arm D1 NMR : 0.259242
Left Arm Q3 power supply current : 278.62
Left Arm Q3 momentum : 0.699841
Left Arm Q3 gauss meter : 0.13939
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0385147
Current on Unser monitor : 11.5193
Current on Upstream bcm : 0.0398634
Current on Downstream bcm : 0.0371659
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 41.3832
Beam energy : 1174.81
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.168498
haBDSPOS : 5.12702e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.06
haSC200_6_Sensor_2_R : -0.03
haSC200_6_Sensor_3_R : 2.82
haSC200_6_Sensor_4_R : 39.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 0
haITC502_1_Sensor_2_R : 0
haITC502_1_Sensor_3_R : 0
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 0
haITC502_6_Sensor_2_R : 0
haITC502_6_Sensor_3_R : 0
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.868604
HacR_HPM_LVDT:VALr : -742
HacR_VPM_LVDT:VALr : -1256
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.822754
HacR_alignROLL : -0.342281
HacR_alignPITCH : -0.0122229
HacR_alignHPT : -1.90603
HacL_HPM_LVDT:VALr : -6931
HacL_VPM_LVDT:VALr : 1238
HacL_HPE1313A:0_Ch58 : -0.194336
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0375977
HacL_alignROLL : 0.376712
HacL_alignPITCH : -0.0918662
HacL_alignHPT : 3.83056
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5543
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5126
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88