keyword=Start_Run_1110_Tar=absence,Type=Pulser,Lmom=1.0,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1110 at Tue Jan 9 12:58:02 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 526.365
Right Arm Q1 momentum : 0.700014
Right Arm Q1 gauss meter : -0.013144
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.375
Right Arm Q2 momentum : 0.700273
Right Arm Q2 gauss meter : 0.15785
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.222
Right Arm D1 momentum : 0.699999
Right Arm D1 NMR : 0.259762
Right Arm Q3 power supply current : 278.536
Right Arm Q3 momentum : 0.700001
Right Arm Q3 gauss meter : 0.12446
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.68
Left Arm Q1 momentum : 0.700064
Left Arm Q1 gauss meter : 0.04517
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 301.334
Left Arm Q2 momentum : 0.699834
Left Arm Q2 gauss meter : -0.15877
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 233.635
Left Arm D1 momentum : 0.700008
Left Arm D1 NMR : 0.259239
Left Arm Q3 power supply current : 278.685
Left Arm Q3 momentum : 0.700004
Left Arm Q3 gauss meter : 0.13937
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0351203
Current on Unser monitor : 10.2352
Current on Upstream bcm : 0.0365976
Current on Downstream bcm : 0.033643
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 59.1404
Beam energy : 1174.81
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.15873
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.48
haSC200_6_Sensor_2_R : 27
haSC200_6_Sensor_3_R : 3.02
haSC200_6_Sensor_4_R : 39.84
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 0
haITC502_1_Sensor_2_R : 0
haITC502_1_Sensor_3_R : 0
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 0
haITC502_6_Sensor_2_R : 0
haITC502_6_Sensor_3_R : 0
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.868604
HacR_HPM_LVDT:VALr : 0
HacR_VPM_LVDT:VALr : -1262
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.822754
HacR_alignROLL : -0.341788
HacR_alignPITCH : -0.0126717
HacR_alignHPT : -1.85482
HacL_HPM_LVDT:VALr : -6939
HacL_VPM_LVDT:VALr : 1242
HacL_HPE1313A:0_Ch58 : -0.193848
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0356445
HacL_alignROLL : 0.375629
HacL_alignPITCH : -0.0921606
HacL_alignHPT : 3.83667
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5539
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5126
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88