Log entry time 17:25:12 on January 9, 2001
Entry number 54145
keyword=Start_Run_1117_Tar=absence,Type=Pulser,Lmom=1.0,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1117 at Tue Jan 9 17:24:56 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : -7.8e-06
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.313
Right Arm Q2 momentum : 0.70013
Right Arm Q2 gauss meter : 0.15787
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.221
Right Arm D1 momentum : 0.7
Right Arm D1 NMR : 0.259762
Right Arm Q3 power supply current : 278.516
Right Arm Q3 momentum : 0.699532
Right Arm Q3 gauss meter : 0.12442
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.19
Left Arm Q1 momentum : 0.699412
Left Arm Q1 gauss meter : 0.04513
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 301.396
Left Arm Q2 momentum : 0.699945
Left Arm Q2 gauss meter : -0.15871
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 233.639
Left Arm D1 momentum : 0.70001
Left Arm D1 NMR : 0.25924
Left Arm Q3 power supply current : 278.682
Left Arm Q3 momentum : 0.699934
Left Arm Q3 gauss meter : 0.13934
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.046865
Current on Unser monitor : 11.4226
Current on Upstream bcm : 0.0559609
Current on Downstream bcm : 0.0377691
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 1174.81
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.17094
haBDSPOS : -1
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 38
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 25.89
haSC200_6_Sensor_3_R : 2.89
haSC200_6_Sensor_4_R : 39.66
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 274.9
haITC502_4_Sensor_2_R : 27
haITC502_4_Sensor_3_R : 69.8
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 282.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 29.49
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.868652
HacR_HPM_LVDT:VALr : -759
HacR_VPM_LVDT:VALr : -1234
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.82373
HacR_alignROLL : -0.343325
HacR_alignPITCH : -0.0139519
HacR_alignHPT : -1.88528
HacL_HPM_LVDT:VALr : -6961
HacL_VPM_LVDT:VALr : 1260
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.0366211
HacL_alignROLL : 0.375164
HacL_alignPITCH : -0.0930337
HacL_alignHPT : 3.82572
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5542
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5127
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88