User name adev
Log entry time 20:10:34 on January 9, 2001
Entry number 54160
keyword=End_of_Run_1125
End-of-run EPICS data for Run Number 1125 at Tue Jan 9 20:10:24 EST 2001
Right Arm D1 momentum : 0.699997
Right Arm arm angle : 12.5536
Left Arm D1 momentum : 0.700009
Left Arm arm angle : 12.5129
Tiefenbach Hall A energy : 1173.86
Right Arm arm mispointing (HPT) : -1.8097
Left Arm arm mispointing (HPT) : 3.78419
Right Arm Q1 power supply current : 526.4
Right Arm Q1 momentum : 0.700061
Right Arm Q1 gauss meter : -0.013146
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.228
Right Arm Q2 momentum : 0.699933
Right Arm Q2 gauss meter : 0.15787
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.221
Right Arm D1 momentum : 0.699999
Right Arm D1 NMR : 0.259761
Right Arm Q3 power supply current : 278.54
Right Arm Q3 momentum : 0.700011
Right Arm Q3 gauss meter : 0.12448
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.19
Left Arm Q1 momentum : 0.699412
Left Arm Q1 gauss meter : 0.04511
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 301.551
Left Arm Q2 momentum : 0.700305
Left Arm Q2 gauss meter : -0.15883
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 233.635
Left Arm D1 momentum : 0.700009
Left Arm D1 NMR : 0.25924
Left Arm Q3 power supply current : 278.657
Left Arm Q3 momentum : 0.699936
Left Arm Q3 gauss meter : 0.13936
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0377468
Current on Unser monitor : 11.4087
Current on Upstream bcm : 0.043595
Current on Downstream bcm : 0.0324504
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 29.6602
MBSY1c Hall A Beam energy : 1174.81
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 293175
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.86
Tiefenbach Hall C energy : 3401.4
Delta(E)/E width (MV_AI_DXWID) : 1.42902
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.868604
HacR_HPM_LVDT:VALr : -823
HacR_VPM_LVDT:VALr : -1279
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.340368
HacR_alignPITCH : -0.0108101
HacR_alignHPT : -1.81197
HacL_HPM_LVDT:VALr : -6893
HacL_VPM_LVDT:VALr : 1252
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0351562
HacL_alignROLL : 0.375629
HacL_alignPITCH : -0.0934703
HacL_alignHPT : 3.78303
haBDSPOS : 190450
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 43.99
haH2_P_Exhaust_R : 44.35
haH2_P_Fill_Bottle_R : 44.4
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.08
haD2_P_Exhaust_R : 35.99
haD2_P_Fill_Bottle_R : 71.3
haD2_DP_Fill_Exhaust_R : 0.0748
haSC200_6_Sensor_1_R : 242.23
haSC200_6_Sensor_2_R : 23.97
haSC200_6_Sensor_3_R : 2.97
haSC200_6_Sensor_4_R : 39.7
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 44.27
haITC502_2_Sensor_2_R : 44.3
haITC502_2_Sensor_3_R : 51.06
haITC502_4_Sensor_1_R : 216.2
haITC502_4_Sensor_2_R : 58.4
haITC502_4_Sensor_3_R : 63.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 279.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.87
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.868652
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : ON