Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 17:47:20 on January 10, 2001
Entry number 54227
keyword=Start_Run_1155_Tar=absence,Type=Cosmic,Lmom=1.0,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1155 at Wed Jan 10 17:46:54 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 819.49
Right Arm Q1 momentum : 1.08984
Right Arm Q1 gauss meter : -0.020471
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 469.259
Right Arm Q2 momentum : 1.09037
Right Arm Q2 gauss meter : 0.2466
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 376.807
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.43644
Right Arm Q3 power supply current : 433.624
Right Arm Q3 momentum : 1.08976
Right Arm Q3 gauss meter : 0.19429
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 819.665
Left Arm Q1 momentum : 1.0895
Left Arm Q1 gauss meter : -0.06934
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 469.531
Left Arm Q2 momentum : 1.09041
Left Arm Q2 gauss meter : 0.248
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 365.037
Left Arm D1 momentum : 1.09001
Left Arm D1 NMR : 0.403531
Left Arm Q3 power supply current : 433.965
Left Arm Q3 momentum : 1.09004
Left Arm Q3 gauss meter : -0.2161
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.63088
Current on Unser monitor : 16.1221
Current on Upstream bcm : 4.63776
Current on Downstream bcm : 4.62401
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 48.7578
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.156288
haBDSPOS : 190449
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.45
haSC200_6_Sensor_2_R : 20.67
haSC200_6_Sensor_3_R : 3.01
haSC200_6_Sensor_4_R : 39.7
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 151.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 276.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.47
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -822
HacR_VPM_LVDT:VALr : -1323
HacR_HPE1313A:0_Ch58 : -0.541016
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.817871
HacR_alignROLL : -0.336801
HacR_alignPITCH : -0.0140846
HacR_alignHPT : -1.81624
HacL_HPM_LVDT:VALr : -6920
HacL_VPM_LVDT:VALr : 1211
HacL_HPE1313A:0_Ch58 : -0.191895
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.0341797
HacL_alignROLL : 0.373925
HacL_alignPITCH : -0.0936175
HacL_alignHPT : 3.81737
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5537
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5127
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 210
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88