User name adev
Log entry time 18:21:50 on January 10, 2001
Entry number 54234
keyword=Start_Run_1158_Tar=carbon,Type=Elastic,Lmom=1.09,Rmom=1.09,Ene=1.173,Angle_R=12.509,Angle_L=12.554
Beginning-of-run EPICS data for Run Number 1158 at Wed Jan 10 18:21:32 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=10000,ps3=100,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 819.385
Right Arm Q1 momentum : 1.0897
Right Arm Q1 gauss meter : -0.020477
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 469.048
Right Arm Q2 momentum : 1.08988
Right Arm Q2 gauss meter : 0.2465
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 372.903
Right Arm D1 momentum : 1.09
Right Arm D1 NMR : 0.404486
Right Arm Q3 power supply current : 433.678
Right Arm Q3 momentum : 1.08989
Right Arm Q3 gauss meter : 0.19432
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 819.7
Left Arm Q1 momentum : 1.08955
Left Arm Q1 gauss meter : -0.06929
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 469.151
Left Arm Q2 momentum : 1.08953
Left Arm Q2 gauss meter : 0.2481
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 365.042
Left Arm D1 momentum : 1.09
Left Arm D1 NMR : 0.40353
Left Arm Q3 power supply current : 433.889
Left Arm Q3 momentum : 1.08985
Left Arm Q3 gauss meter : -0.2162
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 2.54178
Current on Unser monitor : 13.4627
Current on Upstream bcm : 2.59
Current on Downstream bcm : 2.49356
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 47.2758
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.17094
haBDSPOS : 708449
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 32.5
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.05
haSC200_6_Sensor_2_R : 20.12
haSC200_6_Sensor_3_R : 2.76
haSC200_6_Sensor_4_R : 39.55
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 145.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 275.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.42
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -815
HacR_VPM_LVDT:VALr : -1322
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.818848
HacR_alignROLL : -0.33828
HacR_alignPITCH : -0.0136358
HacR_alignHPT : -1.82659
HacL_HPM_LVDT:VALr : -6916
HacL_VPM_LVDT:VALr : 1214
HacL_HPE1313A:0_Ch58 : -0.191406
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.374544
HacL_alignPITCH : -0.0928866
HacL_alignHPT : 0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.5537
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5127
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88