User name adev
Log entry time 19:45:03 on January 10, 2001
Entry number 54239
keyword=End_of_Run_1160
End-of-run EPICS data for Run Number 1160 at Wed Jan 10 19:44:45 EST 2001
Right Arm D1 momentum : 1.09
Right Arm arm angle : 12.5538
Left Arm D1 momentum : 1.09
Left Arm arm angle : 12.5128
Tiefenbach Hall A energy : 1173.67
Right Arm arm mispointing (HPT) : -1.83163
Left Arm arm mispointing (HPT) : 3.80612
Right Arm Q1 power supply current : 819.49
Right Arm Q1 momentum : 1.08984
Right Arm Q1 gauss meter : -0.020475
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 469.122
Right Arm Q2 momentum : 1.09005
Right Arm Q2 gauss meter : 0.2465
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 372.903
Right Arm D1 momentum : 1.09
Right Arm D1 NMR : 0.404486
Right Arm Q3 power supply current : 433.715
Right Arm Q3 momentum : 1.08999
Right Arm Q3 gauss meter : 0.19433
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 819.7
Left Arm Q1 momentum : 1.08955
Left Arm Q1 gauss meter : -0.06932
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 469.204
Left Arm Q2 momentum : 1.08965
Left Arm Q2 gauss meter : 0.2481
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 365.043
Left Arm D1 momentum : 1.09001
Left Arm D1 NMR : 0.403531
Left Arm Q3 power supply current : 433.947
Left Arm Q3 momentum : 1.08999
Left Arm Q3 gauss meter : -0.2162
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0397465
Current on Unser monitor : 10.9939
Current on Upstream bcm : 0.0463661
Current on Downstream bcm : 0.0331269
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 44.4912
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.67
Tiefenbach Hall C energy : 3395.09
Delta(E)/E width (MV_AI_DXWID) : 1.29852
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -810
HacR_VPM_LVDT:VALr : -1304
HacR_HPE1313A:0_Ch58 : -0.54248
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.339382
HacR_alignPITCH : -0.0130542
HacR_alignHPT : -1.83044
HacL_HPM_LVDT:VALr : -6908
HacL_VPM_LVDT:VALr : 1250
HacL_HPE1313A:0_Ch58 : -0.191406
HacL_HPE1313A:0_Ch55 : 0
HacL_HPE1313A:0_Ch54 : 0.0371094
HacL_alignROLL : 0.375938
HacL_alignPITCH : -0.0933232
HacL_alignHPT : 3.80635
haBDSPOS : 708449
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haH2_P_Fill_Target_R : 21.82
haH2_P_Exhaust_R : 22.17
haH2_P_Fill_Bottle_R : 22.15
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.12
haD2_P_Exhaust_R : 19.85
haD2_P_Fill_Bottle_R : 39.13
haD2_DP_Fill_Exhaust_R : 0.0765
haSC200_6_Sensor_1_R : 241.71
haSC200_6_Sensor_2_R : 19.24
haSC200_6_Sensor_3_R : 2.69
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 18.99
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.92
haITC502_4_Sensor_1_R : 133.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 274.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.35
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 120
Laser power Hall A : 57
Half-wave plate (off=out) : OFF