User name adev
Log entry time 22:16:32 on January 10, 2001
Entry number 54250
keyword=End_of_Run_1166
End-of-run EPICS data for Run Number 1166 at Wed Jan 10 22:16:18 EST 2001
Right Arm D1 momentum : 1.217
Right Arm arm angle : 12.5538
Left Arm D1 momentum : 1.217
Left Arm arm angle : 12.5128
Tiefenbach Hall A energy : 1173.61
Right Arm arm mispointing (HPT) : -1.82663
Left Arm arm mispointing (HPT) : 3.80828
Right Arm Q1 power supply current : 915.11
Right Arm Q1 momentum : 1.21701
Right Arm Q1 gauss meter : -0.022835
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 523.726
Right Arm Q2 momentum : 1.21693
Right Arm Q2 gauss meter : 0.2753
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 417.687
Right Arm D1 momentum : 1.217
Right Arm D1 NMR : 0.451613
Right Arm Q3 power supply current : 484.246
Right Arm Q3 momentum : 1.21698
Right Arm Q3 gauss meter : 0.217
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 915.32
Left Arm Q1 momentum : 1.21664
Left Arm Q1 gauss meter : -0.07733
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 523.888
Left Arm Q2 momentum : 1.21665
Left Arm Q2 gauss meter : 0.277
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 408.067
Left Arm D1 momentum : 1.217
Left Arm D1 NMR : 0.450507
Left Arm Q3 power supply current : 484.54
Left Arm Q3 momentum : 1.21707
Left Arm Q3 gauss meter : -0.2415
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.13063
Current on Unser monitor : 16.1694
Current on Upstream bcm : 5.27148
Current on Downstream bcm : 4.98978
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 47.8001
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.61
Tiefenbach Hall C energy : 3395.24
Delta(E)/E width (MV_AI_DXWID) : 1.29708
IPM1C12.XPOS : -0.00399718
IPM1H04A.XPOS : -0.686748
IPM1H04A.YPOS : 0.430585
IPM1H04B.XPOS : 0.0176739
IPM1H04B.YPOS : -0.0418226
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.366113
HacR_HPM_LVDT:VALr : -813
HacR_VPM_LVDT:VALr : -1304
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.818848
HacR_alignROLL : -0.338222
HacR_alignPITCH : -0.0141509
HacR_alignHPT : -1.82775
HacL_HPM_LVDT:VALr : -6912
HacL_VPM_LVDT:VALr : 1229
HacL_HPE1313A:0_Ch58 : -0.191895
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.374235
HacL_alignPITCH : -0.0934703
HacL_alignHPT : 3.8094
haBDSPOS : 708449
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33.5
haL3_Fan_frequency_R : 32.5
haH2_P_Fill_Target_R : 21.82
haH2_P_Exhaust_R : 22.23
haH2_P_Fill_Bottle_R : 22.22
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.14
haD2_P_Exhaust_R : 19.91
haD2_P_Fill_Bottle_R : 39.24
haD2_DP_Fill_Exhaust_R : 0.076
haSC200_6_Sensor_1_R : 242.13
haSC200_6_Sensor_2_R : 18.06
haSC200_6_Sensor_3_R : 2.84
haSC200_6_Sensor_4_R : 39.58
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.92
haITC502_4_Sensor_1_R : 116.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 96.81
haITC502_5_Sensor_2_R : 94.68
haITC502_5_Sensor_3_R : 274.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.31
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.366064
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 168
Laser power Hall A : 57
Half-wave plate (off=out) : OFF