Log entry time 23:32:55 on January 10, 2001
Entry number 54257
keyword=End_of_Run_1169
End-of-run EPICS data for Run Number 1169 at Wed Jan 10 23:32:29 EST 2001
Right Arm D1 momentum : 1.217
Right Arm arm angle : 12.5542
Left Arm D1 momentum : 1.21701
Left Arm arm angle : 12.5125
Tiefenbach Hall A energy : 1173.5
Right Arm arm mispointing (HPT) : -1.89428
Left Arm arm mispointing (HPT) : 3.84303
Right Arm Q1 power supply current : 915.145
Right Arm Q1 momentum : 1.21705
Right Arm Q1 gauss meter : -0.022836
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 523.777
Right Arm Q2 momentum : 1.21705
Right Arm Q2 gauss meter : 0.2753
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 417.694
Right Arm D1 momentum : 1.217
Right Arm D1 NMR : 0.451614
Right Arm Q3 power supply current : 484.015
Right Arm Q3 momentum : 1.21744
Right Arm Q3 gauss meter : 0.2169
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 915.32
Left Arm Q1 momentum : 1.21664
Left Arm Q1 gauss meter : -0.07737
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 524.027
Left Arm Q2 momentum : 1.21718
Left Arm Q2 gauss meter : 0.2769
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 408.072
Left Arm D1 momentum : 1.21701
Left Arm D1 NMR : 0.450509
Left Arm Q3 power supply current : 484.508
Left Arm Q3 momentum : 1.21699
Left Arm Q3 gauss meter : -0.2415
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.74101
Current on Unser monitor : 17.9112
Current on Upstream bcm : 5.79274
Current on Downstream bcm : 5.54246
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 48.3642
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.61
Tiefenbach Hall C energy : 3395
Delta(E)/E width (MV_AI_DXWID) : 1.34598
IPM1C12.XPOS : -0.00627239
IPM1H04A.XPOS : -0.67328
IPM1H04A.YPOS : 0.440643
IPM1H04B.XPOS : 0.0377223
IPM1H04B.YPOS : -0.0475256
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -752
HacR_VPM_LVDT:VALr : -1273
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.339324
HacR_alignPITCH : -0.0140182
HacR_alignHPT : -1.8954
HacL_HPM_LVDT:VALr : -6940
HacL_VPM_LVDT:VALr : 1255
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.373537
HacL_alignPITCH : -0.092813
HacL_alignHPT : 3.84214
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 35.5
haL3_Fan_frequency_R : 32
haH2_P_Fill_Target_R : 21.77
haH2_P_Exhaust_R : 22.15
haH2_P_Fill_Bottle_R : 22.17
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.17
haD2_P_Exhaust_R : 19.84
haD2_P_Fill_Bottle_R : 39.09
haD2_DP_Fill_Exhaust_R : 0.0766
haSC200_6_Sensor_1_R : 241.68
haSC200_6_Sensor_2_R : 17.32
haSC200_6_Sensor_3_R : 2.63
haSC200_6_Sensor_4_R : 39.43
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.93
haITC502_4_Sensor_1_R : 109.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 94.57
haITC502_5_Sensor_2_R : 92.54
haITC502_5_Sensor_3_R : 272.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.15
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868604
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 166
Laser power Hall A : 57
Half-wave plate (off=out) : OFF