User name adev
Log entry time 00:01:41 on January 11, 2001
Entry number 54260
keyword=Start_Run_1171_Tar=9foil-12C,Type=Optics,Lmom=1.193,Rmom=1.193,Ene=1.173,Angle_R=12.509,Angle_L=12.554
Beginning-of-run EPICS data for Run Number 1171 at Thu Jan 11 00:01:14 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=50,ps2=10000,ps3=50,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 896.98
Right Arm Q1 momentum : 1.1929
Right Arm Q1 gauss meter : -0.022386
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 513.649
Right Arm Q2 momentum : 1.19351
Right Arm Q2 gauss meter : 0.27
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 409.019
Right Arm D1 momentum : 1.193
Right Arm D1 NMR : 0.442708
Right Arm Q3 power supply current : 474.745
Right Arm Q3 momentum : 1.1931
Right Arm Q3 gauss meter : 0.2126
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 897.19
Left Arm Q1 momentum : 1.19255
Left Arm Q1 gauss meter : -0.0758
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 513.703
Left Arm Q2 momentum : 1.19299
Left Arm Q2 gauss meter : 0.2715
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 399.912
Left Arm D1 momentum : 1.19301
Left Arm D1 NMR : 0.441635
Left Arm Q3 power supply current : 474.968
Left Arm Q3 momentum : 1.19303
Left Arm Q3 gauss meter : -0.2368
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.66904
Current on Unser monitor : 16.5026
Current on Upstream bcm : 5.66981
Current on Downstream bcm : 5.66827
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 48.5639
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.161172
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 241.81
haSC200_6_Sensor_2_R : 17.33
haSC200_6_Sensor_3_R : 2.74
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 107.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 93.9
haITC502_5_Sensor_2_R : 91.86
haITC502_5_Sensor_3_R : 272.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.14
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -784
HacR_VPM_LVDT:VALr : -1269
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.34031
HacR_alignPITCH : -0.0140182
HacR_alignHPT : -1.85902
HacL_HPM_LVDT:VALr : -6948
HacL_VPM_LVDT:VALr : 1259
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.0341797
HacL_alignROLL : 0.373615
HacL_alignPITCH : -0.0928866
HacL_alignHPT : 3.85104
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 12.554
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5125
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 165
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88