User name adev
Log entry time 02:26:19 on January 11, 2001
Entry number 54266
keyword=Start_Run_1173_Tar=9foil-12C,Type=Optics,Lmom=1.193,Rmom=1.193,Ene=1.173,Angle_R=12.509,Angle_L=12.554
Beginning-of-run EPICS data for Run Number 1173 at Thu Jan 11 02:25:47 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=10000,ps3=10,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 897.05
Right Arm Q1 momentum : 1.19299
Right Arm Q1 gauss meter : -0.022385
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 513.622
Right Arm Q2 momentum : 1.19345
Right Arm Q2 gauss meter : 0.2699
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 409.026
Right Arm D1 momentum : 1.193
Right Arm D1 NMR : 0.442708
Right Arm Q3 power supply current : 474.61
Right Arm Q3 momentum : 1.19276
Right Arm Q3 gauss meter : 0.2126
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 897.19
Left Arm Q1 momentum : 1.19255
Left Arm Q1 gauss meter : -0.07584
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 513.59
Left Arm Q2 momentum : 1.19273
Left Arm Q2 gauss meter : 0.2715
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 399.911
Left Arm D1 momentum : 1.19301
Left Arm D1 NMR : 0.441635
Left Arm Q3 power supply current : 474.891
Left Arm Q3 momentum : 1.19284
Left Arm Q3 gauss meter : -0.2367
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 9.959
Current on Unser monitor : 21.1606
Current on Upstream bcm : 10.0265
Current on Downstream bcm : 9.89149
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 67.275
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.0989
Radiator Encoder : 0.173382
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.11
haSC200_6_Sensor_2_R : 16.47
haSC200_6_Sensor_3_R : 2.79
haSC200_6_Sensor_4_R : 39.56
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 99.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.43
haITC502_5_Sensor_2_R : 89.42
haITC502_5_Sensor_3_R : 272
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.13
Right Arm Arm Collimator : 0.364111
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -796
HacR_VPM_LVDT:VALr : -1275
HacR_HPE1313A:0_Ch58 : -0.540527
HacR_HPE1313A:0_Ch55 : 0
HacR_HPE1313A:0_Ch54 : -0.817871
HacR_alignROLL : -0.337787
HacR_alignPITCH : -0.0149823
HacR_alignHPT : -1.84926
HacL_HPM_LVDT:VALr : -6953
HacL_VPM_LVDT:VALr : 1246
HacL_HPE1313A:0_Ch58 : -0.191406
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.0341797
HacL_alignROLL : 0.374235
HacL_alignPITCH : -0.0934703
HacL_alignHPT : 3.85856
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -27
Right Arm Scattering Angle : 0
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : -49
Left Arm Scattering Angle : 12.5124
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 170
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88