Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 03:54:49 on January 11, 2001
Entry number 54271
keyword=End_of_Run_1175
End-of-run EPICS data for Run Number 1175 at Thu Jan 11 03:54:34 EST 2001
Right Arm D1 momentum : 1.193
Right Arm arm angle : 12.5539
Left Arm D1 momentum : 1.19301
Left Arm arm angle : 12.5127
Tiefenbach Hall A energy : 1173.6
Right Arm arm mispointing (HPT) : -1.84895
Left Arm arm mispointing (HPT) : 3.82318
Right Arm Q1 power supply current : 896.945
Right Arm Q1 momentum : 1.19285
Right Arm Q1 gauss meter : -0.022384
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 513.554
Right Arm Q2 momentum : 1.19329
Right Arm Q2 gauss meter : 0.2699
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 409.027
Right Arm D1 momentum : 1.193
Right Arm D1 NMR : 0.442708
Right Arm Q3 power supply current : 474.685
Right Arm Q3 momentum : 1.19332
Right Arm Q3 gauss meter : 0.2126
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 897.19
Left Arm Q1 momentum : 1.19255
Left Arm Q1 gauss meter : -0.07584
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 513.589
Left Arm Q2 momentum : 1.19273
Left Arm Q2 gauss meter : 0.2715
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 399.916
Left Arm D1 momentum : 1.19301
Left Arm D1 NMR : 0.441636
Left Arm Q3 power supply current : 474.996
Left Arm Q3 momentum : 1.1931
Left Arm Q3 gauss meter : -0.2368
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.43443
Current on Unser monitor : 16.4303
Current on Upstream bcm : 5.52204
Current on Downstream bcm : 5.34682
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 63.0513
MBSY1c Hall A Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
MBSY1c Bdl : 293115
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 1173.6
Tiefenbach Hall C energy : 3395.11
Delta(E)/E width (MV_AI_DXWID) : 1.42299
IPM1C12.XPOS : 0.00973985
IPM1H04A.XPOS : -0.689593
IPM1H04A.YPOS : 0.450583
IPM1H04B.XPOS : 0.0282791
IPM1H04B.YPOS : -0.0470217
Right Arm Arm Collimator : 0.36416
Left Arm Arm Collimator : 0.366064
HacR_HPM_LVDT:VALr : -793
HacR_VPM_LVDT:VALr : -1282
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.819336
HacR_alignROLL : -0.339324
HacR_alignPITCH : -0.0126717
HacR_alignHPT : -1.84951
HacL_HPM_LVDT:VALr : -6921
HacL_VPM_LVDT:VALr : 1246
HacL_HPE1313A:0_Ch58 : -0.192871
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.373924
HacL_alignPITCH : -0.0923028
HacL_alignHPT : 3.82072
haBDSPOS : 708450
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 33
haL3_Fan_frequency_R : 32
haH2_P_Fill_Target_R : 21.64
haH2_P_Exhaust_R : 22.03
haH2_P_Fill_Bottle_R : 22.03
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.2
haD2_P_Exhaust_R : 19.67
haD2_P_Fill_Bottle_R : 38.83
haD2_DP_Fill_Exhaust_R : 0.0767
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 16.14
haSC200_6_Sensor_3_R : 2.66
haSC200_6_Sensor_4_R : 39.5
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 18.92
haITC502_4_Sensor_1_R : 96.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.61
haITC502_5_Sensor_2_R : 88.65
haITC502_5_Sensor_3_R : 273.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.2
Right Arm Arm Collimator : 0.364111
Left Arm Arm Collimator : 0.366064
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 123
Laser power Hall A : 57
Half-wave plate (off=out) : OFF